Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.436 kW
10/31/2025 17:10 (1983 days) Production Consumption NET Usage
Now 0.164 kW 0.600 kW 0.436 kW
Today 11.466 kWh (0.668 kW) 6.838 kWh (0.398 kW) -4.628 kWh (-0.269 kW)
  - This Week 67.574 kWh (11.823 kWh/day) 44.959 kWh (7.866 kWh/day) -22.615 kWh (-3.957 kWh/day)
  - This Month 478.660 kWh (15.584 kWh/day) 469.899 kWh (15.298 kWh/day) -8.761 kWh (-0.285 kWh/day)
  - This Year 5.578 MWh (18.365 kWh/day) 6.325 MWh (20.825 kWh/day) 0.747 MWh (2.459 kWh/day)
Yesterday 1.140 kWh (0.047 kW) 14.195 kWh (0.591 kW) 13.055 kWh (0.544 kW)
Last 7 Days 83.693 kWh (11.956 kWh/day) 45.007 kWh (6.429 kWh/day) -38.686 kWh (-5.526 kWh/day)
Last 30 Days 467.194 kWh (15.573 kWh/day) 463.061 kWh (15.435 kWh/day) -4.133 kWh (-0.138 kWh/day)
Last One Year 6.212 MWh (17.019 kWh/day) 7.401 MWh (20.276 kWh/day) 1.189 MWh (3.257 kWh/day)
Lifetime Since PTO 35.029 MWh (17.658 kW/day) 38.277 MWh (19.296 kW/day) 3.248 MWh (1.637 kW/day)
Lifetime Since Install 35.063 MWh 38.857 MWh 3.794 MWh
Voltage/Current 253.5 V / 0.6 A 253.5 V / 2.4 A 253.5 V / 1.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/04/2021 23:05 (11.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.847 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.511 1.808 7.950 0.000 kW
1.479 kWh
0.000 kW
8.874 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.462 1.751 7.617
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.494 1.783 7.823
04 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.487 1.770 7.756
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.451 1.729 7.586
06 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.468 1.733 7.600
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.672 1.928 8.288 0.000 kW
1.657 kWh
0.000 kW
8.283 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.589 1.766 7.594
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.638 1.973 8.475
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.702 2.012 8.683
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.682 1.986 8.566
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.222 0.911 1.160 5.316 0.000 kW
0.922 kWh
0.000 kW
3.690 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.217 0.915 1.157 5.327
14 - 202216****** IQ7+ [5] VCOP 0.000 0.221 0.941 1.177 5.437
15 - 202245****** IQ7+M [5] VCOP 0.000 0.217 0.924 1.155 5.312
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.14 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 466.5 Ah (23.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 78.9 % State Of Health 98.5 %
Run Time 12d 23h 0m to empty Report Date 2021-03-04 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.