Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.041 kW
02/07/2026 14:56 (2082 days) Production Consumption NET Usage
Now 1.496 kW 0.455 kW -1.041 kW
Today 13.608 kWh (0.910 kW) 5.135 kWh (0.343 kW) -8.473 kWh (-0.567 kW)
  - This Week 107.589 kWh (16.243 kWh/day) 135.366 kWh (20.436 kWh/day) 27.777 kWh (4.194 kWh/day)
  - This Month 107.589 kWh (16.243 kWh/day) 135.366 kWh (20.436 kWh/day) 27.777 kWh (4.194 kWh/day)
  - This Year 0.353 MWh (9.383 kWh/day) 0.719 MWh (19.099 kWh/day) 0.366 MWh (9.716 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 111.729 kWh (17.521 kWh/day) 144.482 kWh (22.657 kWh/day) 32.753 kWh (5.136 kWh/day)
Last 30 Days 273.741 kWh (9.318 kWh/day) 600.538 kWh (20.443 kWh/day) 326.797 kWh (11.124 kWh/day)
Last One Year 6.101 MWh (16.743 kWh/day) 7.569 MWh (20.771 kWh/day) 1.468 MWh (4.028 kWh/day)
Lifetime Since PTO 35.919 MWh (17.247 kW/day) 40.230 MWh (19.317 kW/day) 4.311 MWh (2.070 kW/day)
Lifetime Since Install 35.953 MWh 40.810 MWh 4.857 MWh
Voltage/Current 250.4 V / 6.0 A 250.4 V / 1.8 A 250.4 V / -4.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/20/2021 23:32 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.644 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 1.953 1.588 12.560 0.000 kW
1.855 kWh
0.000 kW
11.133 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.875 1.520 11.915
03 - 202224****** IQ7+M [5] VCOP 0.000 0.299 1.858 1.528 11.919
04 - 202232****** IQ7+ [5] VCOP 0.000 0.300 1.885 1.535 12.040
05 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.667 1.341 10.713
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.895 1.534 12.101
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.693 1.363 10.693 0.000 kW
1.712 kWh
0.000 kW
8.559 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 1.702 1.344 11.006
09 - 202217****** IQ7+ [5] VCOP 0.000 0.301 1.692 1.363 10.930
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.732 1.369 11.145
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.739 1.362 11.172
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.294 2.004 1.688 12.973 0.000 kW
1.988 kWh
0.000 kW
7.952 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.294 1.963 1.679 12.565
14 - 202216****** IQ7+ [5] VCOP 0.000 0.298 2.005 1.688 12.953
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.980 1.669 12.732
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 524.7 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.5 % State Of Health 100.0 %
Run Time 18d 5h 15m to empty Report Date 2021-06-20 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.