Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.139 kW
07/17/2026 04:50 (2242 days) Production Consumption NET Usage
Now 0.226 kW 0.365 kW 0.139 kW
Today 1.097 kWh (0.226 kW) 2.252 kWh (0.464 kW) 1.155 kWh (0.238 kW)
  - This Week 147.124 kWh (28.282 kWh/day) 171.193 kWh (32.909 kWh/day) 24.069 kWh (4.627 kWh/day)
  - This Month 417.678 kWh (25.778 kWh/day) 569.156 kWh (35.127 kWh/day) 151.478 kWh (9.349 kWh/day)
  - This Year 4.028 MWh (20.423 kWh/day) 3.856 MWh (19.553 kWh/day) -0.172 MWh (-0.870 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.714 kWh (28.388 kWh/day) 238.113 kWh (34.016 kWh/day) 39.399 kWh (5.628 kWh/day)
Last 30 Days (06/17/2026) 742.241 kWh (24.741 kWh/day) 864.606 kWh (28.820 kWh/day) 122.365 kWh (4.079 kWh/day)
Last One Year 6.729 MWh (18.436 kWh/day) 7.646 MWh (20.949 kWh/day) 0.917 MWh (2.513 kWh/day)
Lifetime Since PTO 39.593 MWh (17.658 kW/day) 43.367 MWh (19.341 kW/day) 3.774 MWh (1.683 kW/day)
Lifetime Since Install 39.627 MWh 43.947 MWh 4.320 MWh
Voltage/Current 251.5 V / 0.9 A 251.4 V / 1.5 A 251.4 V / 0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/29/2021 22:17 (9.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.106 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.219 0.577 0.157 4.252 0.000 kW
0.571 kWh
0.000 kW
3.428 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.214 0.545 0.139 4.005
03 - 202224****** IQ7+M [0] ---- 0.000 0.220 0.596 0.157 4.260
04 - 202232****** IQ7+ [0] ---- 0.000 0.219 0.579 0.150 4.127
05 - 202244****** IQ7+M [0] ---- 0.000 0.219 0.580 0.143 4.121
06 - 202245****** IQ7+M [0] ---- 0.000 0.218 0.551 0.148 4.079
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.262 0.632 0.144 4.719 0.000 kW
0.629 kWh
0.000 kW
3.143 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.260 0.533 0.143 4.243
09 - 202217****** IQ7+ [0] ---- 0.000 0.261 0.682 0.145 4.989
10 - 202244****** IQ7+M [0] ---- 0.000 0.262 0.659 0.145 4.865
11 - 202224****** IQ7+M [0] ---- 0.000 0.262 0.637 0.145 4.704
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.129 0.373 0.152 2.381 0.000 kW
0.384 kWh
0.000 kW
1.534 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.127 0.385 0.153 2.513
14 - 202216****** IQ7+ [0] ---- 0.000 0.129 0.392 0.156 2.540
15 - 202245****** IQ7+M [0] ---- 0.000 0.127 0.384 0.154 2.492
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.63 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 320.1 Ah (16.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 53.4 % State Of Health 100.0 %
Run Time 11d 2h 44m to empty Report Date 2021-11-29 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.