Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.590 kW
05/30/2026 07:05 (2194 days) Production Consumption NET Usage
Now 0.953 kW 0.363 kW -0.590 kW
Today 2.715 kWh (0.382 kW) 2.905 kWh (0.408 kW) 0.190 kWh (0.027 kW)
  - This Week 161.330 kWh (25.625 kWh/day) 143.619 kWh (22.812 kWh/day) -17.711 kWh (-2.813 kWh/day)
  - This Month 723.325 kWh (24.690 kWh/day) 499.788 kWh (17.060 kWh/day) -223.537 kWh (-7.630 kWh/day)
  - This Year 2.676 MWh (17.927 kWh/day) 2.559 MWh (17.144 kWh/day) -0.117 MWh (-0.783 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 166.049 kWh (23.721 kWh/day) 150.412 kWh (21.487 kWh/day) -15.637 kWh (-2.234 kWh/day)
Last 30 Days (04/30/2026) 732.613 kWh (24.420 kWh/day) 507.313 kWh (16.910 kWh/day) -225.300 kWh (-7.510 kWh/day)
Last One Year 6.429 MWh (17.615 kWh/day) 7.835 MWh (21.466 kWh/day) 1.406 MWh (3.852 kWh/day)
Lifetime Since PTO 38.242 MWh (17.428 kW/day) 42.070 MWh (19.173 kW/day) 3.828 MWh (1.745 kW/day)
Lifetime Since Install 38.276 MWh 42.650 MWh 4.374 MWh
Voltage/Current 251.5 V / 3.8 A 251.5 V / 1.4 A 251.5 V / -2.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/16/2021 22:12 (10.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.234 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.247 0.785 1.310 5.895 0.000 kW
0.758 kWh
0.000 kW
4.550 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.251 0.724 1.279 5.652
03 - 202224****** IQ7+M [5] VCOP 0.000 0.244 0.781 1.306 5.882
04 - 202232****** IQ7+ [5] VCOP 0.000 0.247 0.752 1.277 5.690
05 - 202244****** IQ7+M [5] VCOP 0.000 0.252 0.759 1.277 5.700
06 - 202245****** IQ7+M [5] VCOP 0.000 0.263 0.750 1.270 5.652
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 0.814 1.419 6.183 0.000 kW
0.813 kWh
0.000 kW
4.064 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.280 0.790 1.290 5.903
09 - 202217****** IQ7+ [5] VCOP 0.000 0.282 0.825 1.468 6.294
10 - 202244****** IQ7+M [5] VCOP 0.000 0.275 0.818 1.462 6.283
11 - 202224****** IQ7+M [5] VCOP 0.000 0.280 0.816 1.454 6.267
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.157 0.651 0.853 4.306 0.000 kW
0.655 kWh
0.000 kW
2.620 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.159 0.650 0.866 4.361
14 - 202216****** IQ7+ [5] VCOP 0.000 0.161 0.663 0.877 4.433
15 - 202245****** IQ7+M [5] VCOP 0.000 0.155 0.656 0.865 4.360
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.16 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 495.6 Ah (25.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.6 % State Of Health 100.0 %
Run Time 17d 4h 59m to empty Report Date 2021-10-16 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.