Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 3.169 kW
03/17/2026 16:17 (2120 days) Production Consumption NET Usage
Now 3.714 kW 6.883 kW 3.169 kW
Today 25.938 kWh (1.592 kW) 12.446 kWh (0.764 kW) -13.492 kWh (-0.828 kW)
  - This Week 43.042 kWh (16.067 kWh/day) 39.556 kWh (14.766 kWh/day) -3.486 kWh (-1.301 kWh/day)
  - This Month 277.763 kWh (16.654 kWh/day) 243.583 kWh (14.604 kWh/day) -34.180 kWh (-2.049 kWh/day)
  - This Year 0.912 MWh (12.047 kWh/day) 1.343 MWh (17.751 kWh/day) 0.432 MWh (5.705 kWh/day)
Yesterday 5.215 kWh (0.217 kW) 14.236 kWh (0.593 kW) 9.021 kWh (0.376 kW)
Last 7 Days 127.294 kWh (18.185 kWh/day) 100.327 kWh (14.332 kWh/day) -26.967 kWh (-3.852 kWh/day)
Last 30 Days (02/15/2026) 388.533 kWh (12.951 kWh/day) 451.575 kWh (15.053 kWh/day) 63.042 kWh (2.101 kWh/day)
Last One Year 6.051 MWh (16.579 kWh/day) 7.839 MWh (21.475 kWh/day) 1.787 MWh (4.896 kWh/day)
Lifetime Since PTO 36.477 MWh (17.201 kW/day) 40.854 MWh (19.265 kW/day) 4.377 MWh (2.064 kW/day)
Lifetime Since Install 36.511 MWh 41.434 MWh 4.923 MWh
Voltage/Current 248.5 V / 14.9 A 248.6 V / 27.7 A 248.6 V / 12.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/30/2025 23:46 (23.6 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 23.895 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.231 1.307 0.926 7.140 0.000 kW
1.276 kWh
0.000 kW
7.655 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.220 1.250 0.884 6.807
03 - 202224****** IQ7+M [5] VCOP 0.000 0.228 1.291 0.918 7.035
04 - 202232****** IQ7+ [5] VCOP 0.000 0.231 1.300 0.926 7.094
05 - 202244****** IQ7+M [5] VCOP 0.000 0.220 1.238 0.870 6.689
06 - 202245****** IQ7+M [5] VCOP 0.000 0.222 1.269 0.899 6.895
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.249 1.345 0.859 6.925 0.000 kW
1.385 kWh
0.000 kW
6.926 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.254 1.394 0.894 7.258
09 - 202217****** IQ7+ [5] VCOP 0.000 0.252 1.391 0.898 7.310
10 - 202244****** IQ7+M [5] VCOP 0.000 0.251 1.391 0.896 7.310
11 - 202224****** IQ7+M [5] VCOP 0.000 0.252 1.405 0.902 7.284
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.150 0.912 0.781 5.237 0.000 kW
0.956 kWh
0.000 kW
3.823 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.156 0.948 0.816 5.396
14 - 202216****** IQ7+ [5] VCOP 0.000 0.158 0.980 0.843 5.588
15 - 202245****** IQ7+M [5] VCOP 0.000 0.158 0.982 0.849 5.558
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.746 kWh
0.230 kW
5.492 kWh
17 - 122214****** IQ7PD [4] VCOP 0.230 0.230 5.492 5.498 14.930
Panel Layout Each Group Production

Charger History
Voltage PV 0.48 V Voltage Charge 52.59 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.8 °C / 28.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-30 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.87 V Current/Power -6.35 A (-0.336 kW)
Remain Capacity/Energy 340.4 Ah (17.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 57.4 % State Of Health 98.9 %
Run Time 2d 5h 36m to empty Report Date 2025-09-30 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack