Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.107 kW
02/07/2026 12:30 (2082 days) Production Consumption NET Usage
Now 2.658 kW -0.449 kW -3.107 kW
Today 7.335 kWh (0.587 kW) 5.563 kWh (0.445 kW) -1.772 kWh (-0.142 kW)
  - This Week 101.316 kWh (15.535 kWh/day) 135.794 kWh (20.821 kWh/day) 34.478 kWh (5.287 kWh/day)
  - This Month 101.316 kWh (15.535 kWh/day) 135.794 kWh (20.821 kWh/day) 34.478 kWh (5.287 kWh/day)
  - This Year 0.347 MWh (9.241 kWh/day) 0.719 MWh (19.162 kWh/day) 0.372 MWh (9.921 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 111.489 kWh (17.210 kWh/day) 145.871 kWh (22.517 kWh/day) 34.382 kWh (5.307 kWh/day)
Last 30 Days 279.116 kWh (9.469 kWh/day) 601.815 kWh (20.416 kWh/day) 322.699 kWh (10.947 kWh/day)
Last One Year 6.108 MWh (16.760 kWh/day) 7.570 MWh (20.768 kWh/day) 1.461 MWh (4.009 kWh/day)
Lifetime Since PTO 35.912 MWh (17.244 kW/day) 40.230 MWh (19.318 kW/day) 4.318 MWh (2.073 kW/day)
Lifetime Since Install 35.946 MWh 40.810 MWh 4.864 MWh
Voltage/Current 251.8 V / 10.6 A 251.7 V / -1.8 A 251.7 V / -12.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/30/2021 23:25 (14.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.791 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 2.177 0.765 10.758 0.000 kW
2.097 kWh
0.000 kW
12.582 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.085 0.730 10.340
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.114 0.753 10.523
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.138 0.755 10.597
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.970 0.691 9.731
06 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.098 0.733 10.381
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.967 0.664 9.719 0.000 kW
2.031 kWh
0.000 kW
10.155 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 2.046 0.654 9.806
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 2.001 0.672 9.795
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.063 0.676 9.946
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.079 0.671 9.946
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.290 2.051 0.809 10.668 0.000 kW
2.013 kWh
0.000 kW
8.053 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.289 1.949 0.813 10.425
14 - 202216****** IQ7+ [5] VCOP 0.000 0.288 2.044 0.825 10.706
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 2.009 0.816 10.582
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.