Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.171 kW
01/15/2025 04:44 (1694 days) Production Consumption NET Usage
Now 0.000 kW 0.171 kW 0.171 kW
Today 0.000 kWh (0.000 kW) 2.215 kWh (0.467 kW) 2.215 kWh (0.467 kW)
  - This Week 33.103 kWh (10.352 kWh/day) 100.144 kWh (31.317 kWh/day) 67.041 kWh (20.965 kWh/day)
  - This Month 137.840 kWh (9.709 kWh/day) 361.134 kWh (25.436 kWh/day) 223.294 kWh (15.727 kWh/day)
  - This Year 0.138 MWh (9.709 kWh/day) 0.361 MWh (25.436 kWh/day) 0.223 MWh (15.727 kWh/day)
Yesterday 14.643 kWh (0.610 kW) 20.179 kWh (0.840 kW) 5.536 kWh (0.231 kW)
Last 7 Days 78.633 kWh (11.233 kWh/day) 188.736 kWh (26.962 kWh/day) 110.103 kWh (15.729 kWh/day)
Last 30 Days 242.161 kWh (8.066 kWh/day) 723.450 kWh (24.097 kWh/day) 481.289 kWh (16.031 kWh/day)
Last One Year 6.737 MWh (18.458 kWh/day) 6.364 MWh (17.437 kWh/day) -0.373 MWh (-1.022 kWh/day)
Lifetime Since PTO 29.589 MWh (17.464 kW/day) 32.314 MWh (19.073 kW/day) 2.725 MWh (1.608 kW/day)
Lifetime Since Install 29.623 MWh 32.894 MWh 3.271 MWh
Voltage/Current 250.6 V / 0.0 A 250.5 V / 0.7 A 250.5 V / 0.7 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 07/17/2020 23:33 (13.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.107 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.293 0.996 1.653 11.642 0.000 kW
0.990 kWh
0.000 kW
5.942 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.291 0.984 1.638 11.345
03 - 202224101754 IQ7+M ---- 0.000 0.292 1.003 1.667 11.388
04 - 202232127100 IQ7+ ---- 0.000 0.293 0.993 1.657 11.412
05 - 202244171601 IQ7+M ---- 0.000 0.292 0.983 1.617 10.636
06 - 202245013024 IQ7+M ---- 0.000 0.290 0.982 1.642 11.429
front 07 - 202206091803 IQ7+ ---- 0.000 0.294 0.944 1.543 10.352 0.000 kW
0.972 kWh
0.000 kW
4.860 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.293 0.976 1.634 10.819
09 - 202217001404 IQ7+ ---- 0.000 0.292 0.954 1.596 10.585
10 - 202244165234 IQ7+M ---- 0.000 0.294 0.990 1.653 10.912
11 - 202224104308 IQ7+M ---- 0.000 0.294 0.995 1.646 10.905
back 12 - 202211186551 IQ7+ ---- 0.000 0.246 0.831 1.444 11.448 0.000 kW
0.826 kWh
0.000 kW
3.305 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.249 0.803 1.395 11.056
14 - 202216155993 IQ7+ ---- 0.000 0.248 0.843 1.465 11.438
15 - 202245015670 IQ7+M ---- 0.000 0.241 0.829 1.444 11.259
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 52.43 V Current/Power 163.74 A (8.585 kW)
Remain Capacity/Energy 286.5 Ah (14.7 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 49.6 % State Of Health 96.2 %
Run Time 1h 46m to full Report Date 2020-07-17 23:14
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.43 V Cell (MIN/MAX) 3.272 V / 3.281 V (0.009 V)
Current/Power -0.56 A (-29 W) Runtime 7d 2h 32m to empty
Remain Capacity/Energy 95.5 Ah (4.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 49.6 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-17 23:14
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.272 V 3.272 V 3.273 V 3.273 V 3.275 V 3.275 V 3.275 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.277 V 3.277 V 3.278 V 3.279 V 3.280 V 3.280 V 3.280 V 3.281 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -