Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.919 kW
05/30/2026 06:56 (2194 days) Production Consumption NET Usage
Now 0.744 kW 1.663 kW 0.919 kW
Today 2.582 kWh (0.371 kW) 2.780 kWh (0.399 kW) 0.198 kWh (0.028 kW)
  - This Week 161.197 kWh (25.629 kWh/day) 143.494 kWh (22.815 kWh/day) -17.703 kWh (-2.815 kWh/day)
  - This Month 723.192 kWh (24.691 kWh/day) 499.663 kWh (17.059 kWh/day) -223.529 kWh (-7.632 kWh/day)
  - This Year 2.676 MWh (17.926 kWh/day) 2.559 MWh (17.144 kWh/day) -0.117 MWh (-0.783 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 165.939 kWh (23.706 kWh/day) 150.283 kWh (21.469 kWh/day) -15.656 kWh (-2.237 kWh/day)
Last 30 Days (04/30/2026) 732.485 kWh (24.416 kWh/day) 507.207 kWh (16.907 kWh/day) -225.278 kWh (-7.509 kWh/day)
Last One Year 6.429 MWh (17.614 kWh/day) 7.835 MWh (21.466 kWh/day) 1.406 MWh (3.852 kWh/day)
Lifetime Since PTO 38.242 MWh (17.428 kW/day) 42.070 MWh (19.173 kW/day) 3.828 MWh (1.745 kW/day)
Lifetime Since Install 38.276 MWh 42.650 MWh 4.374 MWh
Voltage/Current 250.6 V / 3.0 A 250.7 V / 6.6 A 250.6 V / 3.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/30/2021 21:30 (8.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.458 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.097 0.316 0.577 4.521 0.000 kW
0.303 kWh
0.000 kW
1.818 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.084 0.285 0.545 4.259
03 - 202224****** IQ7+M [5] VCOP 0.000 0.097 0.312 0.596 4.545
04 - 202232****** IQ7+ [5] VCOP 0.000 0.097 0.308 0.579 4.407
05 - 202244****** IQ7+M [5] VCOP 0.000 0.094 0.294 0.580 4.412
06 - 202245****** IQ7+M [5] VCOP 0.000 0.093 0.303 0.551 4.333
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.102 0.302 0.632 5.071 0.000 kW
0.296 kWh
0.000 kW
1.479 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.086 0.280 0.533 4.493
09 - 202217****** IQ7+ [5] VCOP 0.000 0.101 0.302 0.682 5.382
10 - 202244****** IQ7+M [5] VCOP 0.000 0.101 0.305 0.659 5.235
11 - 202224****** IQ7+M [5] VCOP 0.000 0.099 0.291 0.637 5.055
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.076 0.291 0.373 2.466 0.000 kW
0.290 kWh
0.000 kW
1.161 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.078 0.288 0.385 2.610
14 - 202216****** IQ7+ [5] VCOP 0.000 0.078 0.294 0.392 2.637
15 - 202245****** IQ7+M [5] VCOP 0.000 0.076 0.288 0.384 2.584
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.54 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 304.5 Ah (15.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 50.8 % State Of Health 100.0 %
Run Time 14d 2h 20m to empty Report Date 2021-11-30 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack