Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.085 kW
07/01/2025 13:42 (1861 days) Production Consumption NET Usage
Now 1.906 kW 0.821 kW -1.085 kW
Today 13.555 kWh (0.987 kW) 14.434 kWh (1.051 kW) 0.879 kWh (0.064 kW)
  - This Week 70.841 kWh (27.548 kWh/day) 82.116 kWh (31.932 kWh/day) 11.275 kWh (4.384 kWh/day)
  - This Month 13.555 kWh (23.684 kWh/day) 14.434 kWh (25.219 kWh/day) 0.879 kWh (1.536 kWh/day)
  - This Year 3.043 MWh (16.761 kWh/day) 3.142 MWh (17.303 kWh/day) 0.098 MWh (0.542 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.494 MWh (17.455 kW/day) 35.094 MWh (18.852 kW/day) 2.599 MWh (1.396 kW/day)
Lifetime Since Install 32.528 MWh 35.674 MWh 3.146 MWh
Voltage/Current 247.4 V / 7.7 A 247.4 V / 3.3 A 247.4 V / -4.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/04/2021 21:47 (8.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.943 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.212 0.485 0.050 3.271 0.000 kW
0.450 kWh
0.000 kW
2.699 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.432 0.042 3.021
03 - 202224****** IQ7+M [5] VCOP 0.000 0.206 0.419 0.046 3.083
04 - 202232****** IQ7+ [5] VCOP 0.000 0.173 0.377 0.047 3.036
05 - 202244****** IQ7+M [5] VCOP 0.000 0.204 0.474 0.046 3.163
06 - 202245****** IQ7+M [5] VCOP 0.000 0.204 0.511 0.053 3.298
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.253 0.609 0.047 3.994 0.000 kW
0.583 kWh
0.000 kW
2.915 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.255 0.484 0.042 3.621
09 - 202217****** IQ7+ [5] VCOP 0.000 0.258 0.619 0.041 4.223
10 - 202244****** IQ7+M [5] VCOP 0.000 0.259 0.619 0.041 4.205
11 - 202224****** IQ7+M [5] VCOP 0.000 0.255 0.583 0.040 3.978
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.102 0.316 0.053 1.797 0.000 kW
0.332 kWh
0.000 kW
1.329 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.108 0.340 0.050 1.932
14 - 202216****** IQ7+ [5] VCOP 0.000 0.108 0.342 0.050 1.938
15 - 202245****** IQ7+M [5] VCOP 0.000 0.106 0.332 0.049 1.891
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.18 V Current/Power 166.07 A (8.831 kW)
Remain Capacity/Energy 433.8 Ah (22.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 73.4 % State Of Health 98.5 %
Run Time 56m to full Report Date 2021-01-04 23:49
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.18 V Cell (MIN/MAX) 3.317 V / 3.328 V (0.011 V)
Current/Power -0.25 A (-13 W) Runtime 24d 2h 24m to empty
Remain Capacity/Energy 144.6 Ah (7.4 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 73.4 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-04 23:49
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.319 V 3.320 V 3.320 V 3.321 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.325 V 3.326 V 3.326 V 3.327 V 3.327 V 3.328 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -