Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.234 kW
02/07/2026 12:08 (2082 days) Production Consumption NET Usage
Now 2.611 kW -0.623 kW -3.234 kW
Today 6.315 kWh (0.520 kW) 5.762 kWh (0.475 kW) -0.553 kWh (-0.046 kW)
  - This Week 100.296 kWh (15.415 kWh/day) 135.993 kWh (20.901 kWh/day) 35.697 kWh (5.486 kWh/day)
  - This Month 100.296 kWh (15.415 kWh/day) 135.993 kWh (20.901 kWh/day) 35.697 kWh (5.486 kWh/day)
  - This Year 0.346 MWh (9.218 kWh/day) 0.719 MWh (19.175 kWh/day) 0.373 MWh (9.957 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 111.250 kWh (17.133 kWh/day) 146.139 kWh (22.506 kWh/day) 34.889 kWh (5.373 kWh/day)
Last 30 Days 280.130 kWh (9.498 kWh/day) 601.967 kWh (20.410 kWh/day) 321.837 kWh (10.912 kWh/day)
Last One Year 6.110 MWh (16.762 kWh/day) 7.570 MWh (20.768 kWh/day) 1.460 MWh (4.006 kWh/day)
Lifetime Since PTO 35.911 MWh (17.244 kW/day) 40.231 MWh (19.318 kW/day) 4.319 MWh (2.074 kW/day)
Lifetime Since Install 35.945 MWh 40.811 MWh 4.865 MWh
Voltage/Current 250.8 V / 10.4 A 250.9 V / -2.5 A 250.9 V / -12.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/19/2021 22:57 (13.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.334 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.290 1.200 1.053 10.829 0.000 kW
1.050 kWh
0.000 kW
6.300 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 0.370 1.029 9.948
03 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.197 1.051 10.770
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.197 1.053 10.778
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.152 1.030 10.240
06 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.183 1.033 10.471
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.165 1.053 10.297 0.000 kW
1.173 kWh
0.000 kW
5.863 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.165 1.037 10.400
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.165 1.049 10.309
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.179 1.051 10.500
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.189 1.050 10.656
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.289 1.046 0.899 9.768 0.000 kW
1.043 kWh
0.000 kW
4.171 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 1.023 0.863 9.371
14 - 202216****** IQ7+ [5] VCOP 0.000 0.288 1.058 0.916 9.787
15 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.044 0.911 9.648
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.19 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 511.2 Ah (26.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 85.2 % State Of Health 100.0 %
Run Time 14d 4h 48m to empty Report Date 2021-08-19 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.