Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.049 kW
01/15/2025 00:16 (1694 days) Production Consumption NET Usage
Now 0.000 kW 0.049 kW 0.049 kW
Today 0.000 kWh (0.000 kW) 0.149 kWh (0.520 kW) 0.149 kWh (0.520 kW)
  - This Week 33.103 kWh (10.991 kWh/day) 98.078 kWh (32.563 kWh/day) 64.975 kWh (21.572 kWh/day)
  - This Month 137.840 kWh (9.837 kWh/day) 359.068 kWh (25.626 kWh/day) 221.228 kWh (15.788 kWh/day)
  - This Year 0.138 MWh (9.837 kWh/day) 0.359 MWh (25.626 kWh/day) 0.221 MWh (15.788 kWh/day)
Yesterday 14.643 kWh (0.610 kW) 20.179 kWh (0.840 kW) 5.536 kWh (0.231 kW)
Last 7 Days 78.633 kWh (11.233 kWh/day) 188.736 kWh (26.962 kWh/day) 110.103 kWh (15.729 kWh/day)
Last 30 Days 242.161 kWh (8.066 kWh/day) 723.450 kWh (24.097 kWh/day) 481.289 kWh (16.031 kWh/day)
Last One Year 6.737 MWh (18.458 kWh/day) 6.364 MWh (17.437 kWh/day) -0.373 MWh (-1.022 kWh/day)
Lifetime Since PTO 29.589 MWh (17.466 kW/day) 32.312 MWh (19.074 kW/day) 2.723 MWh (1.607 kW/day)
Lifetime Since Install 29.623 MWh 32.892 MWh 3.269 MWh
Voltage/Current 248.3 V / 0.0 A 248.3 V / 0.2 A 248.3 V / 0.2 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 07/30/2020 23:14 (13.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.405 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.292 1.544 2.127 12.541 0.000 kW
1.495 kWh
0.000 kW
8.968 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.289 1.493 2.052 12.146
03 - 202224101754 IQ7+M ---- 0.000 0.291 1.511 2.069 12.247
04 - 202232127100 IQ7+ ---- 0.000 0.292 1.520 2.092 12.343
05 - 202244171601 IQ7+M ---- 0.000 0.291 1.405 1.924 11.444
06 - 202245013024 IQ7+M ---- 0.000 0.287 1.495 2.062 12.202
front 07 - 202206091803 IQ7+ ---- 0.000 0.288 1.372 1.923 11.329 0.000 kW
1.378 kWh
0.000 kW
6.891 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.288 1.367 2.011 11.639
09 - 202217001404 IQ7+ ---- 0.000 0.287 1.381 1.948 11.461
10 - 202244165234 IQ7+M ---- 0.000 0.287 1.391 2.021 11.740
11 - 202224104308 IQ7+M ---- 0.000 0.286 1.380 2.031 11.729
back 12 - 202211186551 IQ7+ ---- 0.000 0.264 1.644 1.969 12.069 0.000 kW
1.636 kWh
0.000 kW
6.546 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.261 1.634 1.864 11.677
14 - 202216155993 IQ7+ ---- 0.000 0.263 1.645 1.963 12.076
15 - 202245015670 IQ7+M ---- 0.000 0.257 1.622 1.930 11.882
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 56.53 V Current/Power 176.53 A (9.979 kW)
Remain Capacity/Energy 577.2 Ah (29.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-30 23:39
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.53 V Cell (MIN/MAX) 3.526 V / 3.537 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 192.4 Ah (9.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = OFF, DFET = ON Reported 2020-07-30 23:39
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.528 V 3.531 V 3.532 V 3.528 V 3.534 V 3.533 V 3.531 V 3.535 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.530 V 3.526 V 3.533 V 3.533 V 3.533 V 3.537 V 3.537 V 3.537 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -