Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.522 kW
04/09/2026 09:59 (2143 days) Production Consumption NET Usage
Now 2.794 kW 0.272 kW -2.522 kW
Today 6.042 kWh (0.604 kW) 4.857 kWh (0.486 kW) -1.185 kWh (-0.119 kW)
  - This Week 117.046 kWh (26.501 kWh/day) 61.489 kWh (13.922 kWh/day) -55.557 kWh (-12.579 kWh/day)
  - This Month 169.651 kWh (20.156 kWh/day) 122.548 kWh (14.560 kWh/day) -47.103 kWh (-5.596 kWh/day)
  - This Year 1.399 MWh (14.216 kWh/day) 1.688 MWh (17.150 kWh/day) 0.289 MWh (2.935 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 156.644 kWh (22.378 kWh/day) 101.320 kWh (14.474 kWh/day) -55.324 kWh (-7.903 kWh/day)
Last 30 Days (03/10/2026) 633.678 kWh (21.123 kWh/day) 449.477 kWh (14.983 kWh/day) -184.201 kWh (-6.140 kWh/day)
Last One Year 6.173 MWh (16.912 kWh/day) 7.832 MWh (21.457 kWh/day) 1.659 MWh (4.545 kWh/day)
Lifetime Since PTO 36.965 MWh (17.246 kW/day) 41.199 MWh (19.221 kW/day) 4.234 MWh (1.975 kW/day)
Lifetime Since Install 36.999 MWh 41.779 MWh 4.780 MWh
Voltage/Current 252.1 V / 11.1 A 252.2 V / 1.1 A 252.2 V / -10.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/02/2021 21:21 (9.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.430 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.158 0.453 1.108 5.652 0.000 kW
0.439 kWh
0.000 kW
2.633 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.155 0.424 1.017 5.285
03 - 202224****** IQ7+M [5] VCOP 0.000 0.152 0.454 1.061 5.584
04 - 202232****** IQ7+ [5] VCOP 0.000 0.163 0.449 1.014 5.366
05 - 202244****** IQ7+M [5] VCOP 0.000 0.155 0.429 1.089 5.520
06 - 202245****** IQ7+M [5] VCOP 0.000 0.147 0.423 1.058 5.348
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.169 0.433 1.397 6.181 0.000 kW
0.435 kWh
0.000 kW
2.176 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.162 0.431 1.335 5.768
09 - 202217****** IQ7+ [5] VCOP 0.000 0.166 0.437 1.434 6.375
10 - 202244****** IQ7+M [5] VCOP 0.000 0.167 0.439 1.391 6.278
11 - 202224****** IQ7+M [5] VCOP 0.000 0.166 0.436 1.420 6.238
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.115 0.400 0.525 3.735 0.000 kW
0.405 kWh
0.000 kW
1.622 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.113 0.403 0.582 3.875
14 - 202216****** IQ7+ [5] VCOP 0.000 0.115 0.412 0.591 3.927
15 - 202245****** IQ7+M [5] VCOP 0.000 0.114 0.406 0.578 3.858
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.01 V Current/Power -15.33 A (-0.813 kW)
Remain Capacity/Energy 392.7 Ah (20.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 65.5 % State Of Health 100.0 %
Run Time 1d 1h 36m to empty Report Date 2021-11-02 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.