Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.692 kW
01/15/2025 00:08 (1694 days) Production Consumption NET Usage
Now 0.000 kW 0.692 kW 0.692 kW
Today 0.000 kWh 0.102 kWh 0.102 kWh
  - This Week 33.103 kWh (11.011 kWh/day) 98.031 kWh (32.609 kWh/day) 64.928 kWh (21.597 kWh/day)
  - This Month 137.840 kWh (9.841 kWh/day) 359.021 kWh (25.633 kWh/day) 221.181 kWh (15.791 kWh/day)
  - This Year 0.138 MWh (9.841 kWh/day) 0.359 MWh (25.633 kWh/day) 0.221 MWh (15.791 kWh/day)
Yesterday 14.643 kWh (0.610 kW) 20.179 kWh (0.840 kW) 5.536 kWh (0.231 kW)
Last 7 Days 78.633 kWh (11.233 kWh/day) 188.736 kWh (26.962 kWh/day) 110.103 kWh (15.729 kWh/day)
Last 30 Days 242.161 kWh (8.066 kWh/day) 723.450 kWh (24.097 kWh/day) 481.289 kWh (16.031 kWh/day)
Last One Year 6.737 MWh (18.458 kWh/day) 6.364 MWh (17.437 kWh/day) -0.373 MWh (-1.022 kWh/day)
Lifetime Since PTO 29.589 MWh (17.466 kW/day) 32.312 MWh (19.074 kW/day) 2.723 MWh (1.607 kW/day)
Lifetime Since Install 29.623 MWh 32.892 MWh 3.269 MWh
Voltage/Current 249.0 V / 0.0 A 248.9 V / 2.8 A 249.0 V / 2.8 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 08/27/2020 22:24 (12.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.658 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.275 1.746 1.815 12.788 0.000 kW
1.729 kWh
0.000 kW
10.373 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.272 1.721 1.784 12.558
03 - 202224101754 IQ7+M ---- 0.000 0.276 1.745 1.824 12.808
04 - 202232127100 IQ7+ ---- 0.000 0.274 1.732 1.839 12.875
05 - 202244171601 IQ7+M ---- 0.000 0.276 1.711 1.697 12.028
06 - 202245013024 IQ7+M ---- 0.000 0.273 1.718 1.734 12.326
front 07 - 202206091803 IQ7+ ---- 0.000 0.293 1.743 1.726 12.319 0.000 kW
1.761 kWh
0.000 kW
8.806 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.292 1.764 1.686 12.302
09 - 202217001404 IQ7+ ---- 0.000 0.292 1.743 1.725 12.312
10 - 202244165234 IQ7+M ---- 0.000 0.293 1.782 1.756 12.575
11 - 202224104308 IQ7+M ---- 0.000 0.292 1.773 1.752 12.602
back 12 - 202211186551 IQ7+ ---- 0.000 0.229 1.385 1.742 11.500 0.000 kW
1.370 kWh
0.000 kW
5.479 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.227 1.339 1.715 11.133
14 - 202216155993 IQ7+ ---- 0.000 0.228 1.389 1.736 11.504
15 - 202245015670 IQ7+M ---- 0.000 0.229 1.366 1.708 11.321
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 48.10 V Current/Power 150.22 A (7.226 kW)
Remain Capacity/Energy 29.4 Ah (1.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 5.0 % State Of Health 98.5 %
Run Time 3h 44m to full Report Date 2020-08-27 23:45
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 48.10 V Cell (MIN/MAX) 3.000 V / 3.013 V (0.013 V)
Current/Power -0.56 A (-27 W) Runtime 17h 21m to empty
Remain Capacity/Energy 9.8 Ah (0.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 5.0 % State Of Health 98.5 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-27 23:45
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.000 V 3.000 V 3.000 V 3.001 V 3.010 V 3.002 V 3.010 V 3.012 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.000 V 3.007 V 3.006 V 3.010 V 3.003 V 3.011 V 3.012 V 3.013 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -