Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.853 kW
02/07/2026 09:26 (2082 days) Production Consumption NET Usage
Now 1.163 kW 0.310 kW -0.853 kW
Today 1.184 kWh (0.125 kW) 4.586 kWh (0.485 kW) 3.402 kWh (0.360 kW)
  - This Week 95.165 kWh (14.882 kWh/day) 134.817 kWh (21.083 kWh/day) 39.652 kWh (6.201 kWh/day)
  - This Month 95.165 kWh (14.882 kWh/day) 134.817 kWh (21.083 kWh/day) 39.652 kWh (6.201 kWh/day)
  - This Year 0.341 MWh (9.108 kWh/day) 0.718 MWh (19.201 kWh/day) 0.377 MWh (10.093 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 109.717 kWh (16.608 kWh/day) 147.083 kWh (22.265 kWh/day) 37.366 kWh (5.656 kWh/day)
Last 30 Days 285.651 kWh (9.648 kWh/day) 605.021 kWh (20.435 kWh/day) 319.370 kWh (10.787 kWh/day)
Last One Year 6.115 MWh (16.773 kWh/day) 7.570 MWh (20.763 kWh/day) 1.455 MWh (3.991 kWh/day)
Lifetime Since PTO 35.906 MWh (17.242 kW/day) 40.229 MWh (19.318 kW/day) 4.323 MWh (2.076 kW/day)
Lifetime Since Install 35.940 MWh 40.809 MWh 4.869 MWh
Voltage/Current 252.6 V / 4.6 A 252.4 V / 1.2 A 252.5 V / -3.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/11/2021 21:34 (10.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.418 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.286 1.164 0.211 4.052 0.000 kW
1.139 kWh
0.000 kW
6.833 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.285 1.102 0.199 3.856
03 - 202224****** IQ7+M [5] VCOP 0.000 0.283 1.174 0.212 4.054
04 - 202232****** IQ7+ [5] VCOP 0.000 0.285 1.138 0.209 3.971
05 - 202244****** IQ7+M [5] VCOP 0.000 0.278 1.137 0.196 3.869
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.119 0.202 3.876
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.282 0.187 3.918 0.000 kW
1.278 kWh
0.000 kW
6.392 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.274 0.186 3.731
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.285 0.188 3.966
10 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.267 0.190 4.000
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.284 0.187 3.964
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.194 0.783 0.206 3.523 0.000 kW
0.798 kWh
0.000 kW
3.193 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.196 0.799 0.208 3.540
14 - 202216****** IQ7+ [5] VC-- 0.000 0.200 0.815 0.212 3.601
15 - 202245****** IQ7+M [5] VCOP 0.000 0.195 0.796 0.209 3.545
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.