Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.008 kW
07/01/2025 07:33 (1861 days) Production Consumption NET Usage
Now 0.390 kW 0.382 kW -0.008 kW
Today 0.173 kWh (0.023 kW) 6.025 kWh (0.795 kW) 5.852 kWh (0.772 kW)
  - This Week 57.459 kWh (24.820 kWh/day) 73.707 kWh (31.838 kWh/day) 16.248 kWh (7.018 kWh/day)
  - This Month 0.173 kWh (0.548 kWh/day) 6.025 kWh (19.077 kWh/day) 5.852 kWh (18.529 kWh/day)
  - This Year 3.030 MWh (16.711 kWh/day) 3.133 MWh (17.281 kWh/day) 0.103 MWh (0.570 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.450 kW/day) 35.085 MWh (18.850 kW/day) 2.604 MWh (1.399 kW/day)
Lifetime Since Install 32.515 MWh 35.665 MWh 3.151 MWh
Voltage/Current 249.4 V / 1.6 A 249.4 V / 1.5 A 249.4 V / -0.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/24/2025 23:20 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.568 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.012 0.052 0.033 1.461 0.000 kW
0.052 kWh
0.000 kW
0.313 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.011 0.050 0.028 1.363
03 - 202224****** IQ7+M [5] VCOP 0.000 0.011 0.050 0.029 1.426
04 - 202232****** IQ7+ [5] VCOP 0.000 0.014 0.059 0.033 1.436
05 - 202244****** IQ7+M [5] VCOP 0.000 0.012 0.052 0.027 1.351
06 - 202245****** IQ7+M [5] VCOP 0.000 0.013 0.051 0.026 1.386
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.262 0.998 0.409 1.943 0.000 kW
1.233 kWh
0.000 kW
6.164 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.230 0.793 0.133 1.804
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 1.355 0.190 1.902
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.542 0.794 2.496
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.475 0.529 2.218
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.005 0.020 0.011 0.792 0.000 kW
0.023 kWh
0.000 kW
0.091 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.005 0.019 0.013 0.898
14 - 202216****** IQ7+ [5] VCOP 0.000 0.005 0.025 0.017 0.962
15 - 202245****** IQ7+M [5] VCOP 0.000 0.006 0.028 0.019 0.960
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 0.62 V Voltage Charge 52.83 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.3 °C / 23.1 °C Flags 00/00/00 Energy Today 6.873 kWh @ 2025-01-24 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.08 V Current/Power -6.27 A (-0.333 kW)
Remain Capacity/Energy 513.6 Ah (26.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 86.6 % State Of Health 98.9 %
Run Time 3d 9h 54m to empty Report Date 2025-01-24 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.