Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.011 kW
02/07/2026 08:05 (2082 days) Production Consumption NET Usage
Now 0.513 kW 0.524 kW 0.011 kW
Today 0.226 kWh (0.028 kW) 3.722 kWh (0.460 kW) 3.496 kWh (0.432 kW)
  - This Week 94.207 kWh (14.864 kWh/day) 133.953 kWh (21.135 kWh/day) 39.746 kWh (6.271 kWh/day)
  - This Month 94.207 kWh (14.864 kWh/day) 133.953 kWh (21.135 kWh/day) 39.746 kWh (6.271 kWh/day)
  - This Year 0.340 MWh (9.096 kWh/day) 0.717 MWh (19.207 kWh/day) 0.378 MWh (10.111 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 109.529 kWh (16.438 kWh/day) 147.045 kWh (22.068 kWh/day) 37.516 kWh (5.630 kWh/day)
Last 30 Days 286.320 kWh (9.652 kWh/day) 605.720 kWh (20.419 kWh/day) 319.400 kWh (10.767 kWh/day)
Last One Year 6.117 MWh (16.773 kWh/day) 7.571 MWh (20.762 kWh/day) 1.454 MWh (3.988 kWh/day)
Lifetime Since PTO 35.905 MWh (17.242 kW/day) 40.229 MWh (19.319 kW/day) 4.323 MWh (2.076 kW/day)
Lifetime Since Install 35.939 MWh 40.809 MWh 4.869 MWh
Voltage/Current 248.9 V / 2.1 A 249.0 V / 2.1 A 248.9 V / 0.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/12/2021 17:23 (10.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.904 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.275 0.912 1.164 5.055 0.000 kW
0.884 kWh
0.000 kW
5.303 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.275 0.887 1.102 4.807
03 - 202224****** IQ7+M [5] VCOP 0.000 0.277 0.905 1.174 5.066
04 - 202232****** IQ7+ [5] VCOP 0.000 0.279 0.845 1.138 4.950
05 - 202244****** IQ7+M [5] VCOP 0.000 0.274 0.881 1.137 4.857
06 - 202245****** IQ7+M [5] VCOP 0.000 0.270 0.872 1.119 4.841
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.001 1.282 5.058 0.000 kW
0.993 kWh
0.000 kW
4.966 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 0.983 1.274 4.866
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 0.988 1.285 5.109
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.000 1.267 5.122
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 0.995 1.284 5.106
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.210 0.646 0.783 4.148 0.000 kW
0.659 kWh
0.000 kW
2.634 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.209 0.661 0.799 4.179
14 - 202216****** IQ7+ [0] -C-- 0.000 0.204 0.669 0.815 4.252
15 - 202245****** IQ7+M [5] VC-- 0.000 0.210 0.659 0.796 4.180
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 54.55 V Current/Power 4.80 A (0.262 kW)
Remain Capacity/Energy 517.2 Ah (26.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.2 % State Of Health 100.0 %
Run Time 17h 14m to full Report Date 2021-10-12 18:03
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.