Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.124 kW
10/30/2025 12:49 (1982 days) Production Consumption NET Usage
Now 0.188 kW 0.312 kW 0.124 kW
Today 0.700 kWh (0.055 kW) 4.900 kWh (0.382 kW) 4.200 kWh (0.327 kW)
  - This Week 55.668 kWh (12.276 kWh/day) 28.826 kWh (6.357 kWh/day) -26.842 kWh (-5.919 kWh/day)
  - This Month 466.754 kWh (15.804 kWh/day) 453.766 kWh (15.364 kWh/day) -12.988 kWh (-0.440 kWh/day)
  - This Year 5.566 MWh (18.398 kWh/day) 6.309 MWh (20.853 kWh/day) 0.743 MWh (2.455 kWh/day)
Yesterday 11.376 kWh (0.474 kW) 11.476 kWh (0.478 kW) 0.100 kWh (0.004 kW)
Last 7 Days 93.174 kWh (13.311 kWh/day) 38.710 kWh (5.530 kWh/day) -54.464 kWh (-7.781 kWh/day)
Last 30 Days 484.507 kWh (16.150 kWh/day) 462.665 kWh (15.422 kWh/day) -21.842 kWh (-0.728 kWh/day)
Last One Year 6.226 MWh (17.056 kWh/day) 7.399 MWh (20.270 kWh/day) 1.173 MWh (3.214 kWh/day)
Lifetime Since PTO 35.017 MWh (17.663 kW/day) 38.261 MWh (19.299 kW/day) 3.244 MWh (1.636 kW/day)
Lifetime Since Install 35.051 MWh 38.841 MWh 3.790 MWh
Voltage/Current 253.3 V / 0.7 A 253.4 V / 1.2 A 253.3 V / 0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/05/2021 20:35 (14.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.778 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.803 1.621 10.676 0.000 kW
1.738 kWh
0.000 kW
10.427 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.732 1.548 10.198
03 - 202224****** IQ7+M [5] VCOP 0.000 0.282 1.760 1.555 10.295
04 - 202232****** IQ7+ [5] VCOP 0.000 0.281 1.767 1.562 10.378
05 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.618 1.476 9.398
06 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.748 1.574 10.319
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.281 1.569 1.477 9.303 0.000 kW
1.618 kWh
0.000 kW
8.090 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.621 1.496 9.531
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 1.606 1.487 9.457
10 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.645 1.504 9.659
11 - 202224****** IQ7+M [5] VCOP 0.000 0.279 1.649 1.500 9.621
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.272 1.822 1.600 10.797 0.000 kW
1.815 kWh
0.000 kW
7.260 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.270 1.773 1.559 10.491
14 - 202216****** IQ7+ [5] VCOP 0.000 0.273 1.842 1.610 10.815
15 - 202245****** IQ7+M [5] VCOP 0.000 0.269 1.822 1.591 10.632
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.23 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 513.0 Ah (26.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 85.5 % State Of Health 100.0 %
Run Time 17d 19h 29m to empty Report Date 2021-07-05 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.