Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.225 kW
05/30/2026 05:52 (2194 days) Production Consumption NET Usage
Now 0.451 kW 0.226 kW -0.225 kW
Today 1.891 kWh (0.321 kW) 2.443 kWh (0.414 kW) 0.552 kWh (0.094 kW)
  - This Week 160.506 kWh (25.702 kWh/day) 143.157 kWh (22.923 kWh/day) -17.349 kWh (-2.778 kWh/day)
  - This Month 722.501 kWh (24.705 kWh/day) 499.326 kWh (17.074 kWh/day) -223.175 kWh (-7.631 kWh/day)
  - This Year 2.676 MWh (17.927 kWh/day) 2.559 MWh (17.147 kWh/day) -0.116 MWh (-0.781 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 165.313 kWh (23.616 kWh/day) 149.932 kWh (21.419 kWh/day) -15.381 kWh (-2.197 kWh/day)
Last 30 Days (04/30/2026) 731.798 kWh (24.393 kWh/day) 506.761 kWh (16.892 kWh/day) -225.037 kWh (-7.501 kWh/day)
Last One Year 6.429 MWh (17.613 kWh/day) 7.836 MWh (21.467 kWh/day) 1.407 MWh (3.854 kWh/day)
Lifetime Since PTO 38.241 MWh (17.428 kW/day) 42.070 MWh (19.173 kW/day) 3.829 MWh (1.745 kW/day)
Lifetime Since Install 38.275 MWh 42.650 MWh 4.375 MWh
Voltage/Current 251.9 V / 1.8 A 251.9 V / 0.9 A 251.9 V / -0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/05/2022 23:32 (10.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.420 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.289 1.043 0.126 3.854 0.000 kW
1.009 kWh
0.000 kW
6.055 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.280 0.976 0.110 2.653
03 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.012 0.125 3.372
04 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.007 0.121 2.870
05 - 202244****** IQ7+M [5] VCOP 0.000 0.285 1.015 0.114 3.770
06 - 202245****** IQ7+M [5] VCOP 0.000 0.280 1.002 0.117 3.351
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.127 0.113 4.690 0.000 kW
1.144 kWh
0.000 kW
5.720 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 0.975 0.111 4.302
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.224 0.113 4.921
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.228 0.114 4.805
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.166 0.112 4.466
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.174 0.649 0.123 2.678 0.000 kW
0.661 kWh
0.000 kW
2.645 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.176 0.665 0.125 3.086
14 - 202216****** IQ7+ [5] VCOP 0.000 0.178 0.672 0.128 3.107
15 - 202245****** IQ7+M [5] VCOP 0.000 0.171 0.659 0.126 3.044
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.