Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.051 kW
05/30/2026 03:44 (2194 days) Production Consumption NET Usage
Now 0.318 kW 0.369 kW 0.051 kW
Today 1.192 kWh (0.317 kW) 1.532 kWh (0.407 kW) 0.340 kWh (0.090 kW)
  - This Week 159.807 kWh (25.959 kWh/day) 142.246 kWh (23.107 kWh/day) -17.561 kWh (-2.853 kWh/day)
  - This Month 721.802 kWh (24.756 kWh/day) 498.415 kWh (17.095 kWh/day) -223.387 kWh (-7.662 kWh/day)
  - This Year 2.675 MWh (17.933 kWh/day) 2.558 MWh (17.151 kWh/day) -0.117 MWh (-0.782 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 164.614 kWh (23.516 kWh/day) 149.040 kWh (21.291 kWh/day) -15.574 kWh (-2.225 kWh/day)
Last 30 Days (04/30/2026) 731.099 kWh (24.370 kWh/day) 506.005 kWh (16.867 kWh/day) -225.094 kWh (-7.503 kWh/day)
Last One Year 6.428 MWh (17.611 kWh/day) 7.835 MWh (21.467 kWh/day) 1.407 MWh (3.856 kWh/day)
Lifetime Since PTO 38.241 MWh (17.428 kW/day) 42.069 MWh (19.173 kW/day) 3.828 MWh (1.745 kW/day)
Lifetime Since Install 38.274 MWh 42.649 MWh 4.374 MWh
Voltage/Current 252.0 V / 1.3 A 251.9 V / 1.5 A 251.9 V / 0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/12/2022 23:36 (10.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.558 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.133 1.442 7.649 0.000 kW
1.093 kWh
0.000 kW
6.556 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.292 1.050 1.356 7.138
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.122 1.390 7.467
04 - 202232****** IQ7+ [0] ---- 0.000 0.294 1.084 1.367 7.300
05 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.108 1.417 7.467
06 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.059 1.375 7.326
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.218 1.665 8.495 0.000 kW
1.208 kWh
0.000 kW
6.039 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.083 1.501 7.546
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.261 1.736 9.079
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.238 1.722 8.964
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.240 1.708 8.739
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.188 0.725 0.728 4.388 0.000 kW
0.741 kWh
0.000 kW
2.963 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.189 0.744 0.789 4.623
14 - 202216****** IQ7+ [0] ---- 0.000 0.192 0.754 0.800 4.680
15 - 202245****** IQ7+M [0] ---- 0.000 0.186 0.739 0.785 4.596
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.79 V Current/Power -1.38 A (-72 W)
Remain Capacity/Energy 333.3 Ah (17.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 55.6 % State Of Health 100.0 %
Run Time 10d 1h 31m to empty Report Date 2022-02-12 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.