Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.880 kW
02/07/2026 09:27 (2082 days) Production Consumption NET Usage
Now 1.172 kW 0.292 kW -0.880 kW
Today 1.204 kWh (0.127 kW) 4.591 kWh (0.485 kW) 3.387 kWh (0.358 kW)
  - This Week 95.185 kWh (14.884 kWh/day) 134.822 kWh (21.081 kWh/day) 39.637 kWh (6.198 kWh/day)
  - This Month 95.185 kWh (14.884 kWh/day) 134.822 kWh (21.081 kWh/day) 39.637 kWh (6.198 kWh/day)
  - This Year 0.341 MWh (9.108 kWh/day) 0.718 MWh (19.201 kWh/day) 0.377 MWh (10.092 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 109.717 kWh (16.611 kWh/day) 147.075 kWh (22.267 kWh/day) 37.358 kWh (5.656 kWh/day)
Last 30 Days 285.614 kWh (9.647 kWh/day) 604.839 kWh (20.430 kWh/day) 319.225 kWh (10.783 kWh/day)
Last One Year 6.115 MWh (16.773 kWh/day) 7.570 MWh (20.764 kWh/day) 1.455 MWh (3.991 kWh/day)
Lifetime Since PTO 35.906 MWh (17.242 kW/day) 40.229 MWh (19.318 kW/day) 4.323 MWh (2.076 kW/day)
Lifetime Since Install 35.940 MWh 40.809 MWh 4.869 MWh
Voltage/Current 252.4 V / 4.6 A 252.2 V / 1.2 A 252.3 V / -3.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/24/2021 21:09 (10.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.078 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.234 0.648 0.430 7.977 0.000 kW
0.630 kWh
0.000 kW
3.777 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.621 0.409 7.586
03 - 202224****** IQ7+M [5] VCOP 0.000 0.231 0.642 0.430 7.892
04 - 202232****** IQ7+ [5] VCOP 0.000 0.234 0.630 0.426 7.690
05 - 202244****** IQ7+M [5] VCOP 0.000 0.232 0.614 0.408 7.792
06 - 202245****** IQ7+M [5] VCOP 0.000 0.230 0.621 0.411 7.642
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.290 0.568 0.418 8.642 0.000 kW
0.588 kWh
0.000 kW
2.940 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.286 0.515 0.415 7.755
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 0.630 0.424 9.056
10 - 202244****** IQ7+M [5] VCOP 0.000 0.285 0.631 0.423 8.976
11 - 202224****** IQ7+M [5] VCOP 0.000 0.288 0.597 0.418 8.889
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.172 0.588 0.363 5.237 0.000 kW
0.590 kWh
0.000 kW
2.360 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.168 0.588 0.358 5.346
14 - 202216****** IQ7+ [5] VC-- 0.000 0.169 0.597 0.365 5.427
15 - 202245****** IQ7+M [5] VCOP 0.000 0.174 0.588 0.362 5.340
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 519.6 Ah (26.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.6 % State Of Health 100.0 %
Run Time 18d 0h 59m to empty Report Date 2021-10-24 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.