Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.207 kW
05/12/2026 23:55 (2176 days) Production Consumption NET Usage
Now 0.317 kW 0.110 kW -0.207 kW
Today 41.936 kWh (1.752 kW) 12.151 kWh (0.508 kW) -29.785 kWh (-1.245 kW)
  - This Week 81.781 kWh (27.283 kWh/day) 36.912 kWh (12.314 kWh/day) -44.869 kWh (-14.969 kWh/day)
  - This Month 299.856 kWh (24.994 kWh/day) 154.049 kWh (12.841 kWh/day) -145.807 kWh (-12.154 kWh/day)
  - This Year 2.253 MWh (17.068 kWh/day) 2.214 MWh (16.771 kWh/day) -0.039 MWh (-0.296 kWh/day)
Yesterday 19.729 kWh (0.821 kW) 10.766 kWh (0.448 kW) -8.963 kWh (-0.373 kW)
Last 7 Days 154.554 kWh (22.079 kWh/day) 110.461 kWh (15.780 kWh/day) -44.093 kWh (-6.299 kWh/day)
Last 30 Days (04/12/2026) 708.308 kWh (23.610 kWh/day) 437.729 kWh (14.591 kWh/day) -270.579 kWh (-9.019 kWh/day)
Last One Year 6.299 MWh (17.256 kWh/day) 7.791 MWh (21.346 kWh/day) 1.493 MWh (4.089 kWh/day)
Lifetime Since PTO 37.819 MWh (17.372 kW/day) 41.725 MWh (19.166 kW/day) 3.906 MWh (1.794 kW/day)
Lifetime Since Install 37.852 MWh 42.305 MWh 4.452 MWh
Voltage/Current 252.5 V / 1.3 A 252.5 V / 0.4 A 252.5 V / -0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 12/08/2025 23:58 (23.9 hours) Number of Devices 17 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 14.851 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.174 0.673 0.631 4.505 0.000 kW
0.656 kWh
0.000 kW
3.936 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.166 0.637 0.600 4.316
03 - 202224****** IQ7+M [0] ---- 0.000 0.170 0.671 0.627 4.526
04 - 202232****** IQ7+ [0] ---- 0.000 0.168 0.674 0.629 4.556
05 - 202244****** IQ7+M [0] ---- 0.000 0.165 0.632 0.594 4.337
06 - 202245****** IQ7+M [0] ---- 0.000 0.164 0.649 0.611 4.398
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.198 0.728 0.497 4.531 0.000 kW
0.771 kWh
0.000 kW
3.857 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.204 0.773 0.642 5.221
09 - 202217****** IQ7+ [0] ---- 0.000 0.198 0.796 0.696 5.536
10 - 202244****** IQ7+M [0] ---- 0.000 0.198 0.787 0.689 5.461
11 - 202224****** IQ7+M [0] ---- 0.000 0.205 0.772 0.607 5.153
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.084 0.364 0.386 1.962 0.000 kW
0.394 kWh
0.000 kW
1.574 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.096 0.392 0.412 2.250
14 - 202216****** IQ7+ [0] ---- 0.000 0.100 0.410 0.427 2.351
15 - 202245****** IQ7+M [0] ---- 0.000 0.100 0.408 0.422 2.321
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.742 kWh
0.229 kW
5.484 kWh
17 - 122214****** IQ7PD [0] ---- 0.229 0.230 5.484 2.083 2.083
Panel Layout Each Group Production

Charger History
Voltage PV 0.27 V Voltage Charge 52.55 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.5 °C / 25.1 °C Flags 00/00/00 Energy Today 3.644 kWh @ 2025-12-08 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.82 V Current/Power -6.28 A (-0.332 kW)
Remain Capacity/Energy 387.5 Ah (19.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 65.3 % State Of Health 98.9 %
Run Time 2d 13h 42m to empty Report Date 2025-12-08 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.