Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.159 kW
05/30/2026 03:47 (2194 days) Production Consumption NET Usage
Now 0.318 kW 0.477 kW 0.159 kW
Today 1.206 kWh (0.317 kW) 1.546 kWh (0.406 kW) 0.340 kWh (0.089 kW)
  - This Week 159.821 kWh (25.954 kWh/day) 142.260 kWh (23.102 kWh/day) -17.561 kWh (-2.852 kWh/day)
  - This Month 721.816 kWh (24.755 kWh/day) 498.429 kWh (17.094 kWh/day) -223.387 kWh (-7.661 kWh/day)
  - This Year 2.675 MWh (17.933 kWh/day) 2.558 MWh (17.151 kWh/day) -0.117 MWh (-0.782 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 164.628 kWh (23.518 kWh/day) 149.046 kWh (21.292 kWh/day) -15.582 kWh (-2.226 kWh/day)
Last 30 Days (04/30/2026) 731.113 kWh (24.370 kWh/day) 506.025 kWh (16.867 kWh/day) -225.088 kWh (-7.503 kWh/day)
Last One Year 6.428 MWh (17.611 kWh/day) 7.835 MWh (21.467 kWh/day) 1.407 MWh (3.856 kWh/day)
Lifetime Since PTO 38.241 MWh (17.428 kW/day) 42.069 MWh (19.173 kW/day) 3.828 MWh (1.745 kW/day)
Lifetime Since Install 38.274 MWh 42.649 MWh 4.374 MWh
Voltage/Current 251.9 V / 1.3 A 251.8 V / 1.9 A 251.8 V / 0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/13/2022 23:52 (10.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.904 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.129 0.049 5.717 0.000 kW
1.040 kWh
0.000 kW
6.239 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.002 0.040 5.372
03 - 202224****** IQ7+M [0] ---- 0.000 0.300 1.090 0.046 5.669
04 - 202232****** IQ7+ [0] ---- 0.000 0.299 1.124 0.045 5.524
05 - 202244****** IQ7+M [0] ---- 0.000 0.298 0.979 0.040 5.588
06 - 202245****** IQ7+M [0] ---- 0.000 0.299 0.915 0.041 5.406
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.299 0.984 0.044 5.915 0.000 kW
1.137 kWh
0.000 kW
5.687 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.299 1.099 0.044 6.245
09 - 202217****** IQ7+ [0] ---- 0.000 0.300 1.213 0.047 6.049
10 - 202244****** IQ7+M [0] ---- 0.000 0.300 1.197 0.047 6.065
11 - 202224****** IQ7+M [0] ---- 0.000 0.301 1.193 0.046 6.090
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.248 0.898 0.055 4.268 0.000 kW
0.994 kWh
0.000 kW
3.978 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.245 0.930 0.058 4.218
14 - 202216****** IQ7+ [0] ---- 0.000 0.248 1.036 0.063 4.269
15 - 202245****** IQ7+M [0] ---- 0.000 0.243 1.114 0.065 4.243
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.73 V Current/Power -1.53 A (-80 W)
Remain Capacity/Energy 273.9 Ah (14.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 45.6 % State Of Health 100.0 %
Run Time 7d 11h 1m to empty Report Date 2022-03-13 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.