Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.104 kW
10/29/2025 19:25 (1981 days) Production Consumption NET Usage
Now 0.000 kW 0.104 kW 0.104 kW
Today 11.376 kWh (0.585 kW) 9.330 kWh (0.480 kW) -2.046 kWh (-0.105 kW)
  - This Week 54.968 kWh (14.428 kWh/day) 21.780 kWh (5.717 kWh/day) -33.188 kWh (-8.711 kWh/day)
  - This Month 466.054 kWh (16.177 kWh/day) 446.720 kWh (15.506 kWh/day) -19.334 kWh (-0.671 kWh/day)
  - This Year 5.565 MWh (18.440 kWh/day) 6.302 MWh (20.880 kWh/day) 0.736 MWh (2.440 kWh/day)
Yesterday 9.301 kWh (0.388 kW) 13.812 kWh (0.575 kW) 4.511 kWh (0.188 kW)
Last 7 Days 95.910 kWh (13.701 kWh/day) 35.599 kWh (5.086 kWh/day) -60.311 kWh (-8.616 kWh/day)
Last 30 Days 486.248 kWh (16.208 kWh/day) 466.769 kWh (15.559 kWh/day) -19.479 kWh (-0.649 kWh/day)
Last One Year 6.227 MWh (17.061 kWh/day) 7.399 MWh (20.271 kWh/day) 1.172 MWh (3.210 kWh/day)
Lifetime Since PTO 35.016 MWh (17.669 kW/day) 38.254 MWh (19.302 kW/day) 3.237 MWh (1.634 kW/day)
Lifetime Since Install 35.050 MWh 38.834 MWh 3.784 MWh
Voltage/Current 251.5 V / 0.0 A 251.3 V / 0.4 A 251.4 V / 0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/31/2021 23:31 (12.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.525 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.292 1.301 1.260 9.412 0.000 kW
1.275 kWh
0.000 kW
7.648 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.285 1.264 1.228 9.114
03 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.287 1.272 9.409
04 - 202232****** IQ7+ [0] ---- 0.000 0.291 1.284 1.261 9.461
05 - 202244****** IQ7+M [0] ---- 0.000 0.284 1.255 1.211 8.784
06 - 202245****** IQ7+M [0] ---- 0.000 0.287 1.257 1.214 8.952
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.292 1.241 1.272 9.050 0.000 kW
1.242 kWh
0.000 kW
6.212 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.289 1.224 1.270 8.912
09 - 202217****** IQ7+ [0] ---- 0.000 0.289 1.247 1.278 9.015
10 - 202244****** IQ7+M [0] ---- 0.000 0.286 1.254 1.291 9.155
11 - 202224****** IQ7+M [0] ---- 0.000 0.288 1.246 1.297 9.210
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.244 1.169 1.036 8.560 0.000 kW
1.166 kWh
0.000 kW
4.665 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.241 1.160 0.998 8.336
14 - 202216****** IQ7+ [0] ---- 0.000 0.242 1.175 1.046 8.605
15 - 202245****** IQ7+M [0] ---- 0.000 0.237 1.161 1.026 8.473
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.23 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 498.0 Ah (25.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.0 % State Of Health 100.0 %
Run Time 13d 20h 0m to empty Report Date 2021-08-31 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.