Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.200 kW
10/30/2025 13:45 (1982 days) Production Consumption NET Usage
Now 0.115 kW 0.315 kW 0.200 kW
Today 0.801 kWh (0.058 kW) 5.146 kWh (0.373 kW) 4.345 kWh (0.315 kW)
  - This Week 55.769 kWh (12.193 kWh/day) 29.072 kWh (6.356 kWh/day) -26.697 kWh (-5.837 kWh/day)
  - This Month 466.855 kWh (15.786 kWh/day) 454.012 kWh (15.352 kWh/day) -12.843 kWh (-0.434 kWh/day)
  - This Year 5.566 MWh (18.396 kWh/day) 6.309 MWh (20.851 kWh/day) 0.743 MWh (2.455 kWh/day)
Yesterday 11.376 kWh (0.474 kW) 11.476 kWh (0.478 kW) 0.100 kWh (0.004 kW)
Last 7 Days 93.174 kWh (13.311 kWh/day) 38.710 kWh (5.530 kWh/day) -54.464 kWh (-7.781 kWh/day)
Last 30 Days 484.507 kWh (16.150 kWh/day) 462.665 kWh (15.422 kWh/day) -21.842 kWh (-0.728 kWh/day)
Last One Year 6.226 MWh (17.056 kWh/day) 7.399 MWh (20.270 kWh/day) 1.173 MWh (3.214 kWh/day)
Lifetime Since PTO 35.017 MWh (17.662 kW/day) 38.261 MWh (19.299 kW/day) 3.244 MWh (1.636 kW/day)
Lifetime Since Install 35.051 MWh 38.841 MWh 3.790 MWh
Voltage/Current 252.3 V / 0.5 A 252.2 V / 1.2 A 252.2 V / 0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/04/2021 23:31 (11.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.897 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.290 1.946 1.616 7.663 0.000 kW
1.900 kWh
0.000 kW
11.399 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.900 1.542 7.425
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.950 1.627 7.694
04 - 202232****** IQ7+ [5] VCOP 0.000 0.289 1.947 1.624 7.651
05 - 202244****** IQ7+M [5] VCOP 0.000 0.285 1.830 1.512 7.280
06 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.827 1.499 7.287
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.968 1.519 7.357 0.000 kW
1.970 kWh
0.000 kW
9.848 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.921 1.502 7.279
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.937 1.491 7.340
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.007 1.574 7.496
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.014 1.582 7.517
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.251 1.724 1.556 6.903 0.000 kW
1.663 kWh
0.000 kW
6.650 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.251 1.659 1.528 6.784
14 - 202216****** IQ7+ [5] VCOP 0.000 0.252 1.731 1.560 6.954
15 - 202245****** IQ7+M [5] VCOP 0.000 0.247 1.535 1.532 6.844
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.