Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.406 kW
02/07/2026 03:17 (2082 days) Production Consumption NET Usage
Now 0.000 kW 0.406 kW 0.406 kW
Today 0.000 kWh (0.000 kW) 1.441 kWh (0.437 kW) 1.441 kWh (0.437 kW)
  - This Week 93.981 kWh (15.311 kWh/day) 131.672 kWh (21.452 kWh/day) 37.691 kWh (6.141 kWh/day)
  - This Month 93.981 kWh (15.311 kWh/day) 131.672 kWh (21.452 kWh/day) 37.691 kWh (6.141 kWh/day)
  - This Year 0.339 MWh (9.139 kWh/day) 0.715 MWh (19.249 kWh/day) 0.375 MWh (10.110 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 110.876 kWh (16.157 kWh/day) 146.834 kWh (21.397 kWh/day) 35.958 kWh (5.240 kWh/day)
Last 30 Days 286.355 kWh (9.589 kWh/day) 607.265 kWh (20.335 kWh/day) 320.910 kWh (10.746 kWh/day)
Last One Year 6.117 MWh (16.765 kWh/day) 7.574 MWh (20.758 kWh/day) 1.457 MWh (3.994 kWh/day)
Lifetime Since PTO 35.905 MWh (17.244 kW/day) 40.226 MWh (19.319 kW/day) 4.321 MWh (2.075 kW/day)
Lifetime Since Install 35.939 MWh 40.806 MWh 4.867 MWh
Voltage/Current 250.3 V / 0.0 A 250.3 V / 1.6 A 250.3 V / 1.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/31/2021 23:54 (7.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.683 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.189 0.343 0.194 2.354 0.000 kW
0.334 kWh
0.000 kW
2.003 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.189 0.325 0.177 2.213
03 - 202224****** IQ7+M [0] ---- 0.000 0.187 0.345 0.194 2.363
04 - 202232****** IQ7+ [0] ---- 0.000 0.189 0.329 0.185 2.291
05 - 202244****** IQ7+M [0] ---- 0.000 0.189 0.333 0.181 2.279
06 - 202245****** IQ7+M [0] ---- 0.000 0.188 0.328 0.179 2.244
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.217 0.358 0.185 2.641 0.000 kW
0.330 kWh
0.000 kW
1.652 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.207 0.249 0.184 2.458
09 - 202217****** IQ7+ [0] ---- 0.000 0.231 0.366 0.187 2.731
10 - 202244****** IQ7+M [0] ---- 0.000 0.214 0.352 0.183 2.664
11 - 202224****** IQ7+M [0] ---- 0.000 0.211 0.327 0.186 2.596
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.114 0.252 0.175 1.344 0.000 kW
0.257 kWh
0.000 kW
1.027 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.116 0.257 0.176 1.432
14 - 202216****** IQ7+ [0] ---- 0.000 0.119 0.261 0.180 1.450
15 - 202245****** IQ7+M [0] ---- 0.000 0.121 0.257 0.177 1.420
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.44 V Current/Power -1.23 A (-64 W)
Remain Capacity/Energy 257.4 Ah (13.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 42.9 % State Of Health 100.0 %
Run Time 8d 17h 16m to empty Report Date 2021-12-31 23:50
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.45 V Cell (MIN/MAX) 3.269 V / 3.282 V (0.013 V)
Current/Power -0.39 A (-20 W) Runtime 9d 6h 16m to empty
Remain Capacity/Energy 85.8 Ah (4.4 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 42.9 % State Of Health 100.0 %
Temperature 20.0 °C Cycle 51
MOSFET CFET = ON, DFET = ON Reported 2021-12-31 23:50
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.269 V 3.274 V 3.274 V 3.275 V 3.275 V 3.277 V 3.277 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.278 V 3.279 V 3.279 V 3.280 V 3.281 V 3.282 V 3.282 V 3.282 V
pack voltage and current cell voltages
pack temperature
Voltage 52.44 V Cell (MIN/MAX) 3.277 V / 3.277 V (0.000 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 22.0 °C Cycle 8
MOSFET CFET = ON, DFET = ON Reported 2021-12-31 23:51
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.277 V 3.277 V 3.277 V 3.277 V 3.277 V 3.277 V 3.277 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.277 V 3.277 V 3.277 V 3.277 V 3.277 V 3.277 V 3.277 V 3.277 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_2.png". Check that the process running PHP has enough permission.