Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.115 kW
01/30/2026 04:13 (2074 days) Production Consumption NET Usage
Now 0.317 kW 0.202 kW -0.115 kW
Today 1.338 kWh (0.317 kW) 1.787 kWh (0.424 kW) 0.449 kWh (0.106 kW)
  - This Week 7.926 kWh (1.531 kWh/day) 69.241 kWh (13.376 kWh/day) 61.315 kWh (11.845 kWh/day)
  - This Month 213.824 kWh (7.329 kWh/day) 553.471 kWh (18.970 kWh/day) 339.647 kWh (11.641 kWh/day)
  - This Year 0.214 MWh (7.329 kWh/day) 0.553 MWh (18.970 kWh/day) 0.340 MWh (11.641 kWh/day)
Yesterday 5.645 kWh (0.235 kW) 11.666 kWh (0.486 kW) 6.021 kWh (0.251 kW)
Last 7 Days 28.266 kWh (4.037 kWh/day) 129.177 kWh (18.451 kWh/day) 100.911 kWh (14.414 kWh/day)
Last 30 Days 222.476 kWh (7.416 kWh/day) 568.292 kWh (18.943 kWh/day) 345.816 kWh (11.527 kWh/day)
Last One Year 6.080 MWh (16.658 kWh/day) 7.497 MWh (20.540 kWh/day) 1.417 MWh (3.881 kWh/day)
Lifetime Since PTO 35.780 MWh (17.250 kW/day) 40.065 MWh (19.316 kW/day) 4.285 MWh (2.066 kW/day)
Lifetime Since Install 35.813 MWh 40.645 MWh 4.831 MWh
Voltage/Current 249.5 V / 1.3 A 249.6 V / 0.8 A 249.6 V / -0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/31/2021 23:54 (7.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.682 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.180 0.343 0.194 2.353 0.000 kW
0.334 kWh
0.000 kW
2.003 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.179 0.325 0.177 2.211
03 - 202224****** IQ7+M [0] ---- 0.000 0.179 0.345 0.194 2.362
04 - 202232****** IQ7+ [0] ---- 0.000 0.179 0.329 0.185 2.290
05 - 202244****** IQ7+M [0] ---- 0.000 0.180 0.333 0.181 2.277
06 - 202245****** IQ7+M [0] ---- 0.000 0.181 0.328 0.178 2.243
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.208 0.358 0.185 2.639 0.000 kW
0.330 kWh
0.000 kW
1.651 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.200 0.249 0.184 2.457
09 - 202217****** IQ7+ [0] ---- 0.000 0.213 0.366 0.186 2.729
10 - 202244****** IQ7+M [0] ---- 0.000 0.204 0.352 0.183 2.663
11 - 202224****** IQ7+M [0] ---- 0.000 0.202 0.327 0.186 2.594
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.110 0.252 0.175 1.345 0.000 kW
0.257 kWh
0.000 kW
1.027 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.114 0.257 0.176 1.432
14 - 202216****** IQ7+ [0] ---- 0.000 0.117 0.261 0.180 1.450
15 - 202245****** IQ7+M [0] ---- 0.000 0.116 0.257 0.177 1.421
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.44 V Current/Power -1.23 A (-64 W)
Remain Capacity/Energy 257.4 Ah (13.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 42.9 % State Of Health 100.0 %
Run Time 8d 17h 16m to empty Report Date 2021-12-31 23:50
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.