Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.581 kW
01/13/2025 09:36 (1692 days) Production Consumption NET Usage
Now 0.344 kW 0.925 kW 0.581 kW
Today 0.382 kWh (0.040 kW) 7.030 kWh (0.730 kW) 6.648 kWh (0.690 kW)
  - This Week 12.925 kWh (9.230 kWh/day) 62.545 kWh (44.665 kWh/day) 49.620 kWh (35.435 kWh/day)
  - This Month 117.662 kWh (9.489 kWh/day) 323.535 kWh (26.091 kWh/day) 205.873 kWh (16.602 kWh/day)
  - This Year 0.118 MWh (9.489 kWh/day) 0.324 MWh (26.091 kWh/day) 0.206 MWh (16.602 kWh/day)
Yesterday 12.543 kWh (0.523 kW) 55.515 kWh (2.316 kW) 42.972 kWh (1.792 kW)
Last 7 Days 75.170 kWh (10.740 kWh/day) 190.006 kWh (27.148 kWh/day) 114.836 kWh (16.407 kWh/day)
Last 30 Days 242.254 kWh (8.075 kWh/day) 714.323 kWh (23.812 kWh/day) 472.069 kWh (15.736 kWh/day)
Last One Year 6.729 MWh (18.437 kWh/day) 6.354 MWh (17.408 kWh/day) -0.375 MWh (-1.029 kWh/day)
Lifetime Since PTO 29.569 MWh (17.471 kW/day) 32.276 MWh (19.071 kW/day) 2.708 MWh (1.600 kW/day)
Lifetime Since Install 29.602 MWh 32.856 MWh 3.254 MWh
Voltage/Current 249.8 V / 1.4 A 249.9 V / 3.7 A 249.9 V / 2.3 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 12/22/2020 20:38 (8.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.845 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.089 0.098 0.008 1.118 0.000 kW
0.326 kWh
0.000 kW
1.953 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.172 0.166 0.009 1.075
03 - 202224101754 IQ7+M VCOP 0.000 0.198 0.260 0.022 1.072
04 - 202232127100 IQ7+ VCOP 0.000 0.198 0.332 0.024 1.018
05 - 202244171601 IQ7+M VCOP 0.000 0.192 0.526 0.298 1.399
06 - 202245013024 IQ7+M VCOP 0.000 0.192 0.571 0.369 1.509
front 07 - 202206091803 IQ7+ VCOP 0.000 0.273 0.703 0.517 1.845 0.000 kW
0.699 kWh
0.000 kW
3.493 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.275 0.658 0.100 0.149
09 - 202217001404 IQ7+ VCOP 0.000 0.272 0.718 0.816 2.279
10 - 202244165234 IQ7+M VCOP 0.000 0.275 0.718 0.823 2.370
11 - 202224104308 IQ7+M VCOP 0.000 0.271 0.696 0.301 1.648
back 12 - 202211186551 IQ7+ VCOP 0.000 0.097 0.324 0.237 1.271 0.000 kW
0.350 kWh
0.000 kW
1.399 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.108 0.360 0.276 1.142
14 - 202216155993 IQ7+ VCOP 0.000 0.105 0.362 0.275 1.113
15 - 202245015670 IQ7+M VCOP 0.000 0.102 0.352 0.268 1.931
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 51.98 V Current/Power 162.28 A (8.435 kW)
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Run Time 2h 26m to full Report Date 2020-12-22 15:35
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 51.98 V Cell (MIN/MAX) 3.241 V / 3.254 V (0.013 V)
Current/Power -0.50 A (-26 W) Runtime 5d 8h 30m to empty
Remain Capacity/Energy 64.5 Ah (3.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-22 15:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.241 V 3.242 V 3.244 V 3.244 V 3.249 V 3.245 V 3.249 V 3.249 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.248 V 3.248 V 3.251 V 3.249 V 3.252 V 3.253 V 3.254 V 3.254 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -