Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.212 kW
07/17/2026 00:32 (2242 days) Production Consumption NET Usage
Now 0.226 kW 0.438 kW 0.212 kW
Today 0.123 kWh (0.227 kW) 0.444 kWh (0.819 kW) 0.321 kWh (0.592 kW)
  - This Week 146.150 kWh (29.100 kWh/day) 169.385 kWh (33.726 kWh/day) 23.235 kWh (4.626 kWh/day)
  - This Month 416.704 kWh (26.006 kWh/day) 567.348 kWh (35.408 kWh/day) 150.644 kWh (9.402 kWh/day)
  - This Year 4.027 MWh (20.437 kWh/day) 3.854 MWh (19.562 kWh/day) -0.172 MWh (-0.875 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.712 kWh (28.387 kWh/day) 238.941 kWh (34.134 kWh/day) 40.229 kWh (5.747 kWh/day)
Last 30 Days (06/17/2026) 741.267 kWh (24.709 kWh/day) 862.985 kWh (28.766 kWh/day) 121.718 kWh (4.057 kWh/day)
Last One Year 6.728 MWh (18.433 kWh/day) 7.649 MWh (20.956 kWh/day) 0.921 MWh (2.523 kWh/day)
Lifetime Since PTO 39.592 MWh (17.659 kW/day) 43.365 MWh (19.342 kW/day) 3.773 MWh (1.683 kW/day)
Lifetime Since Install 39.626 MWh 43.945 MWh 4.319 MWh
Voltage/Current 251.1 V / 0.9 A 251.0 V / 1.7 A 251.0 V / 0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/28/2022 23:14 (14.8 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.389 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.243 0.652 9.329 0.000 kW
2.112 kWh
0.000 kW
12.673 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.298 2.097 0.616 8.832
03 - 202224****** IQ7+M [0] ---- 0.000 0.301 2.132 0.654 9.064
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.110 0.633 8.961
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.943 0.625 8.279
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 2.148 0.623 8.895
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.989 0.575 8.300 0.000 kW
1.960 kWh
0.000 kW
9.801 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.893 0.573 8.122
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.902 0.578 8.178
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 2.007 0.596 8.396
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.010 0.593 8.414
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.295 2.262 0.617 9.500 0.000 kW
2.229 kWh
0.000 kW
8.915 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.297 2.159 0.614 9.259
14 - 202216****** IQ7+ [0] ---- 0.000 0.295 2.265 0.632 9.555
15 - 202245****** IQ7+M [0] ---- 0.000 0.295 2.230 0.623 9.404
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.31 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 382.5 Ah (19.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 63.8 % State Of Health 100.0 %
Run Time 10d 15h 0m to empty Report Date 2022-06-28 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.