| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.016 kW | |||
|---|---|---|---|
| 07/16/2026 23:46 (2241 days) | Production | Consumption | NET Usage |
| Now | 0.226 kW | 0.242 kW | 0.016 kW |
| Today | 22.599 kWh (0.950 kW) | 31.412 kWh (1.321 kW) | 8.813 kWh (0.371 kW) |
| - This Week | 145.977 kWh (29.252 kWh/day) | 168.858 kWh (33.837 kWh/day) | 22.881 kWh (4.585 kWh/day) |
| - This Month | 416.531 kWh (26.048 kWh/day) | 566.821 kWh (35.446 kWh/day) | 150.290 kWh (9.398 kWh/day) |
| - This Year | 4.026 MWh (20.439 kWh/day) | 3.854 MWh (19.562 kWh/day) | -0.173 MWh (-0.877 kWh/day) |
| Yesterday | 27.130 kWh (1.130 kW) | 32.592 kWh (1.358 kW) | 5.462 kWh (0.228 kW) |
| Last 7 Days | 198.709 kWh (28.387 kWh/day) | 239.195 kWh (34.171 kWh/day) | 40.486 kWh (5.784 kWh/day) |
| Last 30 Days (06/16/2026) | 741.094 kWh (24.703 kWh/day) | 862.461 kWh (28.749 kWh/day) | 121.367 kWh (4.046 kWh/day) |
| Last One Year | 6.728 MWh (18.433 kWh/day) | 7.650 MWh (20.958 kWh/day) | 0.922 MWh (2.525 kWh/day) |
| Lifetime Since PTO | 39.592 MWh (17.659 kW/day) | 43.364 MWh (19.342 kW/day) | 3.772 MWh (1.683 kW/day) |
| Lifetime Since Install | 39.626 MWh | 43.944 MWh | 4.318 MWh |
| Voltage/Current | 249.9 V / 0.9 A | 249.9 V / 1.0 A | 249.9 V / 0.1 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 06/28/2022 23:14 (14.8 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 31.389 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 2.243 | 0.652 | 9.329 | 0.000 kW 2.112 kWh |
0.000 kW 12.673 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.298 | 2.097 | 0.616 | 8.832 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.301 | 2.132 | 0.654 | 9.064 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 2.110 | 0.633 | 8.961 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 1.943 | 0.625 | 8.279 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 2.148 | 0.623 | 8.895 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.296 | 1.989 | 0.575 | 8.300 | 0.000 kW 1.960 kWh |
0.000 kW 9.801 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 1.893 | 0.573 | 8.122 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 1.902 | 0.578 | 8.178 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 2.007 | 0.596 | 8.396 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 2.010 | 0.593 | 8.414 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.295 | 2.262 | 0.617 | 9.500 | 0.000 kW 2.229 kWh |
0.000 kW 8.915 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 2.159 | 0.614 | 9.259 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.295 | 2.265 | 0.632 | 9.555 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.295 | 2.230 | 0.623 | 9.404 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.31 V | Current/Power | -1.50 A (-79 W) |
| Remain Capacity/Energy | 382.5 Ah (19.6 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 63.8 % | State Of Health | 100.0 % |
| Run Time | 10d 15h 0m to empty | Report Date | 2022-06-28 23:52 |
|
|||
| Voltage | 53.34 V | Cell (MIN/MAX) | 3.327 V / 3.338 V (0.011 V) |
|---|---|---|---|
| Current/Power | -0.47 A (-25 W) | Runtime | 11d 4h 25m to empty |
| Remain Capacity/Energy | 127.5 Ah (6.5 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 63.7 % | State Of Health | 100.0 % |
| Temperature | 24.0 °C | Cycle | 68 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-28 23:52 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.331 V / 3.332 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 23.9 °C | Cycle | 20 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-28 23:56 |
| Voltage | 53.34 V | Cell (MIN/MAX) | 3.332 V / 3.334 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 25.1 °C | Cycle | 21 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-28 23:56 |
| Voltage | 53.28 V | Cell (MIN/MAX) | 3.329 V / 3.331 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 25.3 °C | Cycle | 21 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-28 23:56 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.331 V / 3.332 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.2 Ah (5.1 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.7 % |
| Temperature | 23.9 °C | Cycle | 21 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-28 23:56 |