Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.017 kW
10/29/2025 07:54 (1981 days) Production Consumption NET Usage
Now 0.100 kW 0.117 kW 0.017 kW
Today 0.016 kWh (0.002 kW) 2.772 kWh (0.350 kW) 2.756 kWh (0.348 kW)
  - This Week 43.608 kWh (13.096 kWh/day) 15.222 kWh (4.571 kWh/day) -28.386 kWh (-8.525 kWh/day)
  - This Month 454.694 kWh (16.050 kWh/day) 440.162 kWh (15.537 kWh/day) -14.532 kWh (-0.513 kWh/day)
  - This Year 5.554 MWh (18.431 kWh/day) 6.295 MWh (20.891 kWh/day) 0.741 MWh (2.460 kWh/day)
Yesterday 9.301 kWh (0.388 kW) 13.812 kWh (0.575 kW) 4.511 kWh (0.188 kW)
Last 7 Days 95.910 kWh (13.701 kWh/day) 35.599 kWh (5.086 kWh/day) -60.311 kWh (-8.616 kWh/day)
Last 30 Days 486.248 kWh (16.208 kWh/day) 466.769 kWh (15.559 kWh/day) -19.479 kWh (-0.649 kWh/day)
Last One Year 6.227 MWh (17.061 kWh/day) 7.399 MWh (20.271 kWh/day) 1.172 MWh (3.210 kWh/day)
Lifetime Since PTO 35.005 MWh (17.667 kW/day) 38.247 MWh (19.304 kW/day) 3.242 MWh (1.636 kW/day)
Lifetime Since Install 35.039 MWh 38.827 MWh 3.788 MWh
Voltage/Current 252.7 V / 0.4 A 252.7 V / 0.5 A 252.7 V / 0.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/30/2021 22:02 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.135 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.271 0.583 0.504 4.718 0.000 kW
0.560 kWh
0.000 kW
3.361 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.229 0.527 0.485 4.464
03 - 202224****** IQ7+M [5] VCOP 0.000 0.233 0.577 0.506 4.695
04 - 202232****** IQ7+ [5] VCOP 0.000 0.241 0.558 0.502 4.556
05 - 202244****** IQ7+M [5] VCOP 0.000 0.272 0.569 0.483 4.553
06 - 202245****** IQ7+M [5] VCOP 0.000 0.228 0.547 0.488 4.492
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.285 0.620 0.465 4.728 0.000 kW
0.616 kWh
0.000 kW
3.078 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 0.609 0.438 4.460
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 0.621 0.485 4.921
10 - 202244****** IQ7+M [5] VCOP 0.000 0.263 0.614 0.484 4.885
11 - 202224****** IQ7+M [5] VCOP 0.000 0.286 0.615 0.467 4.795
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.169 0.417 0.455 3.648 0.000 kW
0.424 kWh
0.000 kW
1.696 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.170 0.426 0.457 3.704
14 - 202216****** IQ7+ [5] VCOP 0.000 0.172 0.429 0.464 3.764
15 - 202245****** IQ7+M [5] VCOP 0.000 0.172 0.424 0.458 3.701
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 518.1 Ah (26.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.4 % State Of Health 100.0 %
Run Time 23d 23h 40m to empty Report Date 2021-10-30 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.