Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.311 kW
07/01/2025 04:15 (1861 days) Production Consumption NET Usage
Now 0.000 kW 0.311 kW 0.311 kW
Today 0.000 kWh (0.000 kW) 3.527 kWh (0.825 kW) 3.527 kWh (0.825 kW)
  - This Week 57.286 kWh (26.310 kWh/day) 71.209 kWh (32.704 kWh/day) 13.923 kWh (6.394 kWh/day)
  - This Month 0.000 kWh (0.000 kWh/day) 3.527 kWh (19.801 kWh/day) 3.527 kWh (19.801 kWh/day)
  - This Year 3.030 MWh (16.722 kWh/day) 3.131 MWh (17.280 kWh/day) 0.101 MWh (0.558 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.452 kW/day) 35.083 MWh (18.850 kW/day) 2.602 MWh (1.398 kW/day)
Lifetime Since Install 32.515 MWh 35.663 MWh 3.148 MWh
Voltage/Current 251.6 V / 0.0 A 251.6 V / 1.2 A 251.6 V / 1.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/06/2025 23:23 (8.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 1.322 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.023 0.081 1.304 6.354 0.000 kW
0.077 kWh
0.000 kW
0.464 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.023 0.073 1.237 6.020
03 - 202224****** IQ7+M [0] ---- 0.000 0.024 0.080 1.281 6.254
04 - 202232****** IQ7+ [0] ---- 0.000 0.024 0.081 1.277 6.265
05 - 202244****** IQ7+M [0] ---- 0.000 0.021 0.074 1.242 6.109
06 - 202245****** IQ7+M [0] ---- 0.000 0.023 0.075 1.272 6.239
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.024 0.082 1.429 6.905 0.000 kW
0.102 kWh
0.000 kW
0.510 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.025 0.082 1.572 7.436
09 - 202217****** IQ7+ [0] ---- 0.000 0.034 0.118 1.584 7.849
10 - 202244****** IQ7+M [0] ---- 0.000 0.034 0.114 1.573 7.881
11 - 202224****** IQ7+M [0] ---- 0.000 0.029 0.113 1.589 7.639
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.024 0.078 0.613 3.253 0.000 kW
0.087 kWh
0.000 kW
0.348 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.026 0.085 0.700 3.624
14 - 202216****** IQ7+ [0] ---- 0.000 0.026 0.090 0.719 3.763
15 - 202245****** IQ7+M [0] ---- 0.000 0.031 0.094 0.713 3.733
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.41 V Voltage Charge 52.39 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 25.8 °C / 22.3 °C Flags 00/00/00 Energy Today 0.693 kWh @ 2025-02-06 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.57 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 341.7 Ah (17.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 57.6 % State Of Health 98.9 %
Run Time 9d 11h 48m to empty Report Date 2025-02-06 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.