Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.282 kW
09/13/2025 03:25 (1935 days) Production Consumption NET Usage
Now 0.000 kW 0.282 kW 0.282 kW
Today 0.000 kWh (0.000 kW) 1.303 kWh (0.380 kW) 1.303 kWh (0.380 kW)
  - This Week 126.394 kWh (20.575 kWh/day) 85.967 kWh (13.994 kWh/day) -40.427 kWh (-6.581 kWh/day)
  - This Month 263.322 kWh (21.686 kWh/day) 281.692 kWh (23.198 kWh/day) 18.370 kWh (1.513 kWh/day)
  - This Year 4.771 MWh (18.698 kWh/day) 5.452 MWh (21.370 kWh/day) 0.682 MWh (2.672 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.222 MWh (17.684 kW/day) 37.404 MWh (19.329 kW/day) 3.183 MWh (1.645 kW/day)
Lifetime Since Install 34.255 MWh 37.984 MWh 3.729 MWh
Voltage/Current 253.9 V / 0.0 A 253.9 V / 1.1 A 253.9 V / 1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/13/2021 22:16 (10.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.820 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.072 0.266 0.913 5.560 0.000 kW
0.261 kWh
0.000 kW
1.564 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.070 0.254 0.888 5.305
03 - 202224****** IQ7+M [0] ---- 0.000 0.072 0.269 0.905 5.561
04 - 202232****** IQ7+ [0] ---- 0.000 0.071 0.265 0.846 5.389
05 - 202244****** IQ7+M [0] ---- 0.000 0.069 0.251 0.881 5.349
06 - 202245****** IQ7+M [0] ---- 0.000 0.070 0.259 0.875 5.319
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.065 0.241 1.002 5.692 0.000 kW
0.242 kWh
0.000 kW
1.208 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.063 0.240 0.983 5.484
09 - 202217****** IQ7+ [0] ---- 0.000 0.064 0.243 0.988 5.725
10 - 202244****** IQ7+M [0] ---- 0.000 0.066 0.243 1.000 5.750
11 - 202224****** IQ7+M [0] ---- 0.000 0.065 0.242 0.995 5.731
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.070 0.259 0.645 4.400 0.000 kW
0.262 kWh
0.000 kW
1.048 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.069 0.260 0.660 4.442
14 - 202216****** IQ7+ [0] ---- 0.000 0.070 0.266 0.668 4.517
15 - 202245****** IQ7+M [0] ---- 0.000 0.070 0.264 0.659 4.441
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.18 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 499.2 Ah (25.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.2 % State Of Health 100.0 %
Run Time 13d 20h 48m to empty Report Date 2021-10-13 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.