Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 5.868 kW
03/17/2026 20:03 (2120 days) Production Consumption NET Usage
Now 0.317 kW 6.185 kW 5.868 kW
Today 31.163 kWh (1.554 kW) 37.632 kWh (1.876 kW) 6.469 kWh (0.323 kW)
  - This Week 48.267 kWh (17.022 kWh/day) 64.742 kWh (22.832 kWh/day) 16.475 kWh (5.810 kWh/day)
  - This Month 282.988 kWh (16.809 kWh/day) 268.769 kWh (15.964 kWh/day) -14.219 kWh (-0.845 kWh/day)
  - This Year 0.917 MWh (12.091 kWh/day) 1.369 MWh (18.047 kWh/day) 0.452 MWh (5.956 kWh/day)
Yesterday 5.215 kWh (0.217 kW) 14.236 kWh (0.593 kW) 9.021 kWh (0.376 kW)
Last 7 Days 129.358 kWh (18.480 kWh/day) 122.033 kWh (17.433 kWh/day) -7.325 kWh (-1.046 kWh/day)
Last 30 Days (02/15/2026) 388.120 kWh (12.937 kWh/day) 449.645 kWh (14.988 kWh/day) 61.525 kWh (2.051 kWh/day)
Last One Year 6.050 MWh (16.575 kWh/day) 7.836 MWh (21.470 kWh/day) 1.786 MWh (4.894 kWh/day)
Lifetime Since PTO 36.483 MWh (17.202 kW/day) 40.879 MWh (19.275 kW/day) 4.397 MWh (2.073 kW/day)
Lifetime Since Install 36.516 MWh 41.459 MWh 4.943 MWh
Voltage/Current 247.3 V / 1.3 A 247.2 V / 25.0 A 247.3 V / 23.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/27/2025 23:46 (10.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.644 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.240 1.352 1.109 7.042 0.000 kW
1.310 kWh
0.000 kW
7.858 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.232 1.280 1.066 6.725
03 - 202224****** IQ7+M [0] ---- 0.000 0.239 1.306 1.078 6.919
04 - 202232****** IQ7+ [0] ---- 0.000 0.241 1.303 1.088 6.960
05 - 202244****** IQ7+M [0] ---- 0.000 0.232 1.288 1.079 6.738
06 - 202245****** IQ7+M [0] ---- 0.000 0.236 1.329 1.097 6.896
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.290 1.343 1.158 6.404 0.000 kW
1.528 kWh
0.000 kW
7.639 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.292 1.513 1.273 7.274
09 - 202217****** IQ7+ [0] ---- 0.000 0.288 1.612 1.296 7.675
10 - 202244****** IQ7+M [0] ---- 0.000 0.287 1.596 1.280 7.606
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.575 1.284 7.505
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.138 0.721 0.637 4.722 0.000 kW
0.787 kWh
0.000 kW
3.148 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.141 0.795 0.688 4.994
14 - 202216****** IQ7+ [0] ---- 0.000 0.144 0.819 0.708 5.149
15 - 202245****** IQ7+M [0] ---- 0.000 0.143 0.813 0.697 5.125
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 7.467
Panel Layout Each Group Production

Charger History
Voltage PV 0.56 V Voltage Charge 52.49 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.8 °C / 26.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-27 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.69 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 288.0 Ah (14.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 48.6 % State Of Health 98.9 %
Run Time 6d 16h 0m to empty Report Date 2025-10-27 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.