Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 5.081 kW
03/17/2026 17:39 (2120 days) Production Consumption NET Usage
Now 2.373 kW 7.454 kW 5.081 kW
Today 29.738 kWh (1.683 kW) 21.400 kWh (1.211 kW) -8.338 kWh (-0.472 kW)
  - This Week 46.842 kWh (17.120 kWh/day) 48.510 kWh (17.730 kWh/day) 1.668 kWh (0.610 kWh/day)
  - This Month 281.563 kWh (16.824 kWh/day) 252.537 kWh (15.089 kWh/day) -29.026 kWh (-1.734 kWh/day)
  - This Year 0.915 MWh (12.088 kWh/day) 1.352 MWh (17.856 kWh/day) 0.437 MWh (5.768 kWh/day)
Yesterday 5.215 kWh (0.217 kW) 14.236 kWh (0.593 kW) 9.021 kWh (0.376 kW)
Last 7 Days 128.414 kWh (18.345 kWh/day) 108.075 kWh (15.439 kWh/day) -20.339 kWh (-2.906 kWh/day)
Last 30 Days (02/15/2026) 388.164 kWh (12.939 kWh/day) 451.001 kWh (15.033 kWh/day) 62.837 kWh (2.095 kWh/day)
Last One Year 6.050 MWh (16.576 kWh/day) 7.838 MWh (21.474 kWh/day) 1.788 MWh (4.897 kWh/day)
Lifetime Since PTO 36.481 MWh (17.202 kW/day) 40.863 MWh (19.268 kW/day) 4.382 MWh (2.066 kW/day)
Lifetime Since Install 36.515 MWh 41.443 MWh 4.928 MWh
Voltage/Current 246.8 V / 9.6 A 246.8 V / 30.2 A 246.8 V / 20.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/30/2025 23:52 (10.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 1.199 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.053 0.084 0.803 6.705 0.000 kW
0.081 kWh
0.000 kW
0.485 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.043 0.078 0.752 6.367
03 - 202224****** IQ7+M [5] VCOP 0.000 0.052 0.085 0.766 6.523
04 - 202232****** IQ7+ [5] VCOP 0.000 0.051 0.083 0.760 6.532
05 - 202244****** IQ7+M [5] VCOP 0.000 0.047 0.076 0.752 6.384
06 - 202245****** IQ7+M [5] VCOP 0.000 0.049 0.080 0.796 6.579
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.040 0.077 0.833 6.152 0.000 kW
0.077 kWh
0.000 kW
0.386 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.043 0.077 0.900 7.021
09 - 202217****** IQ7+ [5] VCOP 0.000 0.042 0.077 0.903 7.397
10 - 202244****** IQ7+M [5] VCOP 0.000 0.043 0.078 0.906 7.350
11 - 202224****** IQ7+M [5] VCOP 0.000 0.041 0.076 0.910 7.239
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.048 0.074 0.537 4.431 0.000 kW
0.082 kWh
0.000 kW
0.328 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.048 0.080 0.573 4.701
14 - 202216****** IQ7+ [5] VCOP 0.000 0.048 0.086 0.596 4.852
15 - 202245****** IQ7+M [5] VCOP 0.000 0.046 0.088 0.597 4.824
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 1.18 V Voltage Charge 52.14 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.6 °C / 26.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-30 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.37 V Current/Power -4.97 A (-0.260 kW)
Remain Capacity/Energy 219.9 Ah (11.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 37.1 % State Of Health 98.9 %
Run Time 1d 20h 14m to empty Report Date 2025-10-30 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.