Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.139 kW
05/12/2026 17:25 (2176 days) Production Consumption NET Usage
Now 2.721 kW 0.582 kW -2.139 kW
Today 37.478 kWh (2.151 kW) 8.211 kWh (0.471 kW) -29.267 kWh (-1.680 kW)
  - This Week 77.323 kWh (28.361 kWh/day) 32.972 kWh (12.094 kWh/day) -44.351 kWh (-16.268 kWh/day)
  - This Month 295.398 kWh (25.192 kWh/day) 150.109 kWh (12.801 kWh/day) -145.289 kWh (-12.390 kWh/day)
  - This Year 2.248 MWh (17.069 kWh/day) 2.210 MWh (16.776 kWh/day) -0.039 MWh (-0.293 kWh/day)
Yesterday 19.729 kWh (0.821 kW) 10.766 kWh (0.448 kW) -8.963 kWh (-0.373 kW)
Last 7 Days 151.751 kWh (21.679 kWh/day) 109.596 kWh (15.657 kWh/day) -42.155 kWh (-6.022 kWh/day)
Last 30 Days (04/12/2026) 707.285 kWh (23.576 kWh/day) 439.189 kWh (14.640 kWh/day) -268.096 kWh (-8.937 kWh/day)
Last One Year 6.296 MWh (17.249 kWh/day) 7.795 MWh (21.357 kWh/day) 1.499 MWh (4.108 kWh/day)
Lifetime Since PTO 37.814 MWh (17.372 kW/day) 41.721 MWh (19.167 kW/day) 3.906 MWh (1.795 kW/day)
Lifetime Since Install 37.848 MWh 42.301 MWh 4.453 MWh
Voltage/Current 250.1 V / 10.9 A 250.2 V / 2.3 A 250.2 V / -8.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/11/2022 22:36 (13.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.019 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.877 1.537 12.230 0.000 kW
1.812 kWh
0.000 kW
10.871 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.795 1.468 11.593
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.860 1.538 12.099
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.816 1.526 12.056
05 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.735 1.497 11.336
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.788 1.492 11.648
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.818 1.560 11.714 0.000 kW
1.799 kWh
0.000 kW
8.997 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.755 1.501 11.611
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.774 1.491 11.608
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.828 1.550 11.808
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.822 1.561 11.828
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 1.569 1.299 11.162 0.000 kW
1.538 kWh
0.000 kW
6.151 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.280 1.492 1.213 10.667
14 - 202216****** IQ7+ [5] VCOP 0.000 0.281 1.557 1.314 11.265
15 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.534 1.276 11.007
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.