Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.504 kW
06/30/2025 17:35 (1860 days) Production Consumption NET Usage
Now 2.062 kW 2.566 kW 0.504 kW
Today 26.223 kWh (1.489 kW) 19.306 kWh (1.096 kW) -6.917 kWh (-0.393 kW)
  - This Week 56.181 kWh (32.415 kWh/day) 56.325 kWh (32.498 kWh/day) 0.144 kWh (0.083 kWh/day)
  - This Month 627.470 kWh (21.103 kWh/day) 761.959 kWh (25.626 kWh/day) 134.489 kWh (4.523 kWh/day)
  - This Year 3.029 MWh (16.757 kWh/day) 3.116 MWh (17.240 kWh/day) 0.087 MWh (0.483 kWh/day)
Yesterday 29.958 kWh (1.249 kW) 37.019 kWh (1.543 kW) 7.061 kWh (0.294 kW)
Last 7 Days 164.939 kWh (23.565 kWh/day) 274.127 kWh (39.165 kWh/day) 109.188 kWh (15.600 kWh/day)
Last 30 Days 617.926 kWh (20.598 kWh/day) 775.650 kWh (25.855 kWh/day) 157.724 kWh (5.257 kWh/day)
Last One Year 6.346 MWh (17.387 kWh/day) 6.392 MWh (17.513 kWh/day) 0.046 MWh (0.126 kWh/day)
Lifetime Since PTO 32.479 MWh (17.455 kW/day) 35.068 MWh (18.846 kW/day) 2.588 MWh (1.391 kW/day)
Lifetime Since Install 32.513 MWh 35.648 MWh 3.134 MWh
Voltage/Current 248.5 V / 8.3 A 248.5 V / 10.3 A 248.5 V / 2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/09/2021 22:23 (10.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.252 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.243 0.647 1.068 5.990 0.000 kW
0.629 kWh
0.000 kW
3.776 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.238 0.624 1.041 5.716
03 - 202224****** IQ7+M [5] VCOP 0.000 0.241 0.647 1.063 5.971
04 - 202232****** IQ7+ [5] VCOP 0.000 0.239 0.624 1.045 5.854
05 - 202244****** IQ7+M [5] VCOP 0.000 0.238 0.612 1.020 5.737
06 - 202245****** IQ7+M [5] VCOP 0.000 0.236 0.622 1.000 5.684
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.249 0.587 1.010 6.001 0.000 kW
0.587 kWh
0.000 kW
2.936 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.247 0.550 0.916 5.689
09 - 202217****** IQ7+ [5] VCOP 0.000 0.246 0.601 1.051 6.093
10 - 202244****** IQ7+M [5] VCOP 0.000 0.245 0.604 1.049 6.128
11 - 202224****** IQ7+M [5] VCOP 0.000 0.243 0.595 1.036 6.098
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.196 0.629 0.935 4.841 0.000 kW
0.635 kWh
0.000 kW
2.540 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.196 0.634 0.930 4.824
14 - 202216****** IQ7+ [5] VCOP 0.000 0.196 0.642 0.946 4.918
15 - 202245****** IQ7+M [5] VCOP 0.000 0.191 0.634 0.933 4.831
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.09 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 381.6 Ah (19.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 63.6 % State Of Health 100.0 %
Run Time 8d 20h 0m to empty Report Date 2021-10-09 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.