Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.274 kW
07/01/2025 10:04 (1861 days) Production Consumption NET Usage
Now 2.755 kW 0.481 kW -2.274 kW
Today 2.911 kWh (0.288 kW) 8.024 kWh (0.794 kW) 5.113 kWh (0.506 kW)
  - This Week 60.197 kWh (24.873 kWh/day) 75.706 kWh (31.282 kWh/day) 15.509 kWh (6.408 kWh/day)
  - This Month 2.911 kWh (6.916 kWh/day) 8.024 kWh (19.064 kWh/day) 5.113 kWh (12.148 kWh/day)
  - This Year 3.033 MWh (16.716 kWh/day) 3.135 MWh (17.282 kWh/day) 0.103 MWh (0.566 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.484 MWh (17.451 kW/day) 35.087 MWh (18.850 kW/day) 2.604 MWh (1.399 kW/day)
Lifetime Since Install 32.517 MWh 35.667 MWh 3.150 MWh
Voltage/Current 249.8 V / 11.0 A 249.6 V / 1.9 A 249.7 V / -9.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/28/2021 22:02 (10.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.901 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.232 1.377 0.768 5.189 0.000 kW
1.331 kWh
0.000 kW
7.988 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.228 1.298 0.713 4.943
03 - 202224****** IQ7+M [5] VCOP 0.000 0.231 1.356 0.767 5.154
04 - 202232****** IQ7+ [5] VCOP 0.000 0.232 1.291 0.737 5.025
05 - 202244****** IQ7+M [5] VCOP 0.000 0.230 1.356 0.738 5.011
06 - 202245****** IQ7+M [5] VCOP 0.000 0.226 1.310 0.718 4.944
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.279 1.536 0.764 5.214 0.000 kW
1.539 kWh
0.000 kW
7.697 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.378 0.746 4.816
09 - 202217****** IQ7+ [5] VCOP 0.000 0.278 1.622 0.772 5.478
10 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.587 0.774 5.436
11 - 202224****** IQ7+M [5] VCOP 0.000 0.277 1.573 0.764 5.329
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.141 0.769 0.628 4.008 0.000 kW
0.804 kWh
0.000 kW
3.217 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.140 0.815 0.634 4.049
14 - 202216****** IQ7+ [5] VCOP 0.000 0.142 0.825 0.642 4.115
15 - 202245****** IQ7+M [5] VCOP 0.000 0.139 0.808 0.632 4.050
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.69 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 278.7 Ah (14.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 46.5 % State Of Health 100.0 %
Run Time 6d 10h 50m to empty Report Date 2021-10-28 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.70 V Cell (MIN/MAX) 3.287 V / 3.300 V (0.013 V)
Current/Power -0.60 A (-31 W) Runtime 6d 10h 50m to empty
Remain Capacity/Energy 92.9 Ah (4.8 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 46.5 % State Of Health 100.0 %
Temperature 25.0 °C Cycle 46
MOSFET CFET = ON, DFET = ON Reported 2021-10-28 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.287 V 3.288 V 3.289 V 3.289 V 3.290 V 3.290 V 3.291 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.293 V 3.295 V 3.296 V 3.298 V 3.299 V 3.300 V 3.300 V
pack voltage and current cell voltages
pack temperature
Voltage 52.66 V Cell (MIN/MAX) 3.290 V / 3.292 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 68.6 Ah (3.5 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 68.6 % State Of Health 100.0 %
Temperature 27.4 °C Cycle 6
MOSFET CFET = ON, DFET = ON Reported 2021-10-28 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.292 V 3.290 V 3.292 V 3.292 V 3.292 V 3.291 V 3.290 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.290 V 3.290 V 3.291 V 3.290 V 3.292 V 3.291 V 3.292 V 3.290 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt1_2.png". Check that the process running PHP has enough permission.