Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.554 kW
02/24/2026 14:35 (2099 days) Production Consumption NET Usage
Now 0.000 kW -1.554 kW -1.554 kW
Today 0.000 kWh (0.000 kW) 4.531 kWh (0.310 kW) 4.531 kWh (0.310 kW)
  - This Week 2.648 kWh (1.015 kWh/day) 42.487 kWh (16.291 kWh/day) 39.839 kWh (15.275 kWh/day)
  - This Month 310.363 kWh (13.146 kWh/day) 465.143 kWh (19.702 kWh/day) 154.780 kWh (6.556 kWh/day)
  - This Year 0.556 MWh (10.178 kWh/day) 1.048 MWh (19.197 kWh/day) 0.493 MWh (9.020 kWh/day)
Yesterday 0.244 kWh (0.010 kW) 16.979 kWh (0.707 kW) 16.735 kWh (0.697 kW)
Last 7 Days 32.726 kWh (4.675 kWh/day) 145.803 kWh (20.829 kWh/day) 113.077 kWh (16.154 kWh/day)
Last 30 Days 349.888 kWh (11.663 kWh/day) 551.217 kWh (18.374 kWh/day) 201.329 kWh (6.711 kWh/day)
Last One Year 6.108 MWh (16.733 kWh/day) 7.709 MWh (21.120 kWh/day) 1.601 MWh (4.387 kWh/day)
Lifetime Since PTO 36.121 MWh (17.204 kW/day) 40.560 MWh (19.317 kW/day) 4.438 MWh (2.114 kW/day)
Lifetime Since Install 36.155 MWh 41.140 MWh 4.984 MWh
Voltage/Current 249.5 V / 0.0 A 249.3 V / -6.2 A 249.4 V / -6.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/24/2022 22:09 (14.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.951 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.819 0.773 10.651 0.000 kW
1.740 kWh
0.000 kW
10.440 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.739 0.731 10.107
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.778 0.763 10.347
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.762 0.744 10.176
05 - 202244****** IQ7+M [5] VC-- 0.000 0.298 1.580 0.696 9.596
06 - 202245****** IQ7+M [5] VC-- 0.000 0.298 1.762 0.741 10.178
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.627 0.661 9.552 0.000 kW
1.617 kWh
0.000 kW
8.087 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.299 1.601 0.668 9.284
09 - 202217****** IQ7+ [5] VC-- 0.000 0.298 1.579 0.664 9.351
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.630 0.667 9.580
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.650 0.659 9.679
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.296 1.867 0.802 10.787 0.000 kW
1.856 kWh
0.000 kW
7.424 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.296 1.828 0.807 10.494
14 - 202216****** IQ7+ [5] VCOP 0.000 0.297 1.877 0.821 10.850
15 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.852 0.815 10.693
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.66 V Current/Power -1.59 A (-83 W)
Remain Capacity/Energy 141.6 Ah (7.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 23.6 % State Of Health 100.0 %
Run Time 3d 17h 3m to empty Report Date 2022-06-24 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.65 V Cell (MIN/MAX) 3.285 V / 3.296 V (0.011 V)
Current/Power -0.54 A (-28 W) Runtime 3d 16h 13m to empty
Remain Capacity/Energy 47.2 Ah (2.4 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 23.6 % State Of Health 100.0 %
Temperature 23.0 °C Cycle 68
MOSFET CFET = ON, DFET = ON Reported 2022-06-24 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.285 V 3.286 V 3.286 V 3.287 V 3.288 V 3.288 V 3.289 V 3.289 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.290 V 3.291 V 3.291 V 3.293 V 3.293 V 3.295 V 3.296 V 3.295 V
pack voltage and current cell voltages
pack temperature
Voltage 52.65 V Cell (MIN/MAX) 3.290 V / 3.290 V (0.000 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 52.5 Ah (2.7 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 52.5 % State Of Health 100.0 %
Temperature 22.9 °C Cycle 20
MOSFET CFET = ON, DFET = ON Reported 2022-06-24 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V
pack voltage and current cell voltages
pack temperature
Voltage 52.68 V Cell (MIN/MAX) 3.291 V / 3.293 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 48.2 Ah (2.5 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 48.2 % State Of Health 100.0 %
Temperature 23.9 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-06-24 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.292 V 3.293 V 3.293 V 3.291 V 3.293 V 3.292 V 3.293 V 3.293 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.293 V 3.292 V 3.292 V 3.292 V 3.291 V 3.292 V 3.292 V
pack voltage and current cell voltages
pack temperature
Voltage 52.65 V Cell (MIN/MAX) 3.290 V / 3.291 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 50.1 Ah (2.6 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 50.1 % State Of Health 100.0 %
Temperature 24.1 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-06-24 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.290 V 3.291 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V
pack voltage and current cell voltages
pack temperature
Voltage 52.65 V Cell (MIN/MAX) 3.290 V / 3.291 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 49.3 Ah (2.5 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 49.5 % State Of Health 99.7 %
Temperature 22.9 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-06-24 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.290 V 3.291 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V 3.290 V
pack voltage and current cell voltages
pack temperature