Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.151 kW
01/29/2026 18:32 (2073 days) Production Consumption NET Usage
Now 0.316 kW 0.467 kW 0.151 kW
Today 3.915 kWh (0.211 kW) 8.652 kWh (0.467 kW) 4.737 kWh (0.255 kW)
  - This Week 4.858 kWh (1.018 kWh/day) 64.440 kWh (13.501 kWh/day) 59.582 kWh (12.483 kWh/day)
  - This Month 210.756 kWh (7.325 kWh/day) 548.670 kWh (19.069 kWh/day) 337.914 kWh (11.744 kWh/day)
  - This Year 0.211 MWh (7.325 kWh/day) 0.549 MWh (19.069 kWh/day) 0.338 MWh (11.744 kWh/day)
Yesterday 0.585 kWh (0.024 kW) 10.639 kWh (0.443 kW) 10.054 kWh (0.419 kW)
Last 7 Days 35.412 kWh (5.059 kWh/day) 132.668 kWh (18.952 kWh/day) 97.256 kWh (13.893 kWh/day)
Last 30 Days 225.877 kWh (7.529 kWh/day) 572.426 kWh (19.081 kWh/day) 346.549 kWh (11.551 kWh/day)
Last One Year 6.090 MWh (16.685 kWh/day) 7.496 MWh (20.536 kWh/day) 1.406 MWh (3.852 kWh/day)
Lifetime Since PTO 35.776 MWh (17.252 kW/day) 40.060 MWh (19.317 kW/day) 4.284 MWh (2.066 kW/day)
Lifetime Since Install 35.810 MWh 40.640 MWh 4.830 MWh
Voltage/Current 250.0 V / 1.3 A 250.0 V / 1.9 A 250.0 V / 0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/31/2022 21:51 (14.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.235 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.289 2.088 2.100 12.017 0.000 kW
1.974 kWh
0.000 kW
11.841 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.281 1.965 1.955 11.358
03 - 202224****** IQ7+M [0] ---- 0.000 0.286 1.992 2.012 11.781
04 - 202232****** IQ7+ [0] ---- 0.000 0.285 1.995 1.993 11.619
05 - 202244****** IQ7+M [0] ---- 0.000 0.283 1.812 1.825 11.063
06 - 202245****** IQ7+M [0] ---- 0.000 0.277 1.988 2.003 11.496
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 1.847 1.897 11.018 0.000 kW
1.841 kWh
0.000 kW
9.203 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.801 1.827 10.718
09 - 202217****** IQ7+ [0] ---- 0.000 0.292 1.812 1.850 10.792
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.865 1.922 11.069
11 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.878 1.925 11.186
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.255 2.073 2.102 11.823 0.000 kW
2.048 kWh
0.000 kW
8.191 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.254 2.015 2.018 11.539
14 - 202216****** IQ7+ [0] ---- 0.000 0.254 2.068 2.108 11.948
15 - 202245****** IQ7+M [0] ---- 0.000 0.249 2.034 2.076 11.816
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.