Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.763 kW
07/01/2025 12:01 (1861 days) Production Consumption NET Usage
Now 1.964 kW 2.727 kW 0.763 kW
Today 8.309 kWh (0.690 kW) 11.130 kWh (0.924 kW) 2.821 kWh (0.234 kW)
  - This Week 65.595 kWh (26.224 kWh/day) 78.812 kWh (31.508 kWh/day) 13.217 kWh (5.284 kWh/day)
  - This Month 8.309 kWh (16.549 kWh/day) 11.130 kWh (22.168 kWh/day) 2.821 kWh (5.619 kWh/day)
  - This Year 3.038 MWh (16.738 kWh/day) 3.138 MWh (17.291 kWh/day) 0.100 MWh (0.553 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.489 MWh (17.453 kW/day) 35.090 MWh (18.851 kW/day) 2.601 MWh (1.397 kW/day)
Lifetime Since Install 32.523 MWh 35.670 MWh 3.147 MWh
Voltage/Current 248.1 V / 7.9 A 248.1 V / 11.0 A 248.1 V / 3.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/11/2021 21:46 (9.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.002 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.224 0.793 1.069 7.589 0.000 kW
0.774 kWh
0.000 kW
4.647 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.217 0.750 1.003 7.094
03 - 202224****** IQ7+M [5] VCOP 0.000 0.234 0.794 1.074 7.549
04 - 202232****** IQ7+ [5] VCOP 0.000 0.228 0.791 1.031 7.117
05 - 202244****** IQ7+M [5] VCOP 0.000 0.223 0.772 1.066 7.476
06 - 202245****** IQ7+M [5] VCOP 0.000 0.215 0.746 1.042 7.269
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.262 0.816 1.253 8.600 0.000 kW
0.817 kWh
0.000 kW
4.083 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.272 0.699 1.115 7.552
09 - 202217****** IQ7+ [5] VCOP 0.000 0.271 0.878 1.420 9.533
10 - 202244****** IQ7+M [5] VCOP 0.000 0.266 0.869 1.389 9.306
11 - 202224****** IQ7+M [5] VCOP 0.000 0.266 0.821 1.305 8.893
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.124 0.556 0.497 4.111 0.000 kW
0.568 kWh
0.000 kW
2.272 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.138 0.571 0.565 4.427
14 - 202216****** IQ7+ [5] VCOP 0.000 0.142 0.578 0.569 4.401
15 - 202245****** IQ7+M [5] VCOP 0.000 0.136 0.569 0.557 4.366
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.55 V Current/Power -4.14 A (-0.218 kW)
Remain Capacity/Energy 321.0 Ah (16.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 53.5 % State Of Health 100.0 %
Run Time 3d 5h 32m to empty Report Date 2021-11-11 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.