Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.310 kW
09/17/2025 18:27 (1939 days) Production Consumption NET Usage
Now 0.018 kW 0.328 kW 0.310 kW
Today 10.402 kWh (0.564 kW) 7.690 kWh (0.417 kW) -2.712 kWh (-0.147 kW)
  - This Week 71.288 kWh (18.911 kWh/day) 94.969 kWh (25.193 kWh/day) 23.681 kWh (6.282 kWh/day)
  - This Month 357.057 kWh (21.293 kWh/day) 399.526 kWh (23.825 kWh/day) 42.469 kWh (2.533 kWh/day)
  - This Year 4.864 MWh (18.726 kWh/day) 5.570 MWh (21.443 kWh/day) 0.706 MWh (2.717 kWh/day)
Yesterday 14.819 kWh (0.617 kW) 13.670 kWh (0.569 kW) -1.149 kWh (-0.048 kW)
Last 7 Days 144.530 kWh (20.648 kWh/day) 153.736 kWh (21.963 kWh/day) 9.206 kWh (1.315 kWh/day)
Last 30 Days 672.086 kWh (22.403 kWh/day) 697.605 kWh (23.253 kWh/day) 25.519 kWh (0.851 kWh/day)
Last One Year 6.262 MWh (17.156 kWh/day) 7.162 MWh (19.622 kWh/day) 0.900 MWh (2.466 kWh/day)
Lifetime Since PTO 34.315 MWh (17.690 kW/day) 37.522 MWh (19.344 kW/day) 3.207 MWh (1.653 kW/day)
Lifetime Since Install 34.349 MWh 38.102 MWh 3.753 MWh
Voltage/Current 251.4 V / 0.1 A 251.3 V / 1.3 A 251.3 V / 1.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/31/2022 23:26 (9.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.787 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.247 1.139 0.389 4.596 0.000 kW
0.862 kWh
0.000 kW
5.169 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.125 0.448 0.073 4.061
03 - 202224****** IQ7+M [5] VCOP 0.000 0.244 0.901 0.154 4.368
04 - 202232****** IQ7+ [5] VCOP 0.000 0.189 0.599 0.079 4.199
05 - 202244****** IQ7+M [5] VCOP 0.000 0.245 1.135 0.383 4.506
06 - 202245****** IQ7+M [5] VCOP 0.000 0.240 0.947 0.215 4.188
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.409 0.735 5.630 0.000 kW
1.410 kWh
0.000 kW
7.052 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.303 0.706 5.190
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.488 0.731 5.934
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.456 0.743 5.826
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.396 0.503 5.459
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.160 0.605 0.501 2.761 0.000 kW
0.642 kWh
0.000 kW
2.566 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.161 0.653 0.687 3.247
14 - 202216****** IQ7+ [5] VCOP 0.000 0.163 0.662 0.691 3.255
15 - 202245****** IQ7+M [5] VCOP 0.000 0.161 0.647 0.675 3.179
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.