Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.531 kW
02/03/2026 11:04 (2078 days) Production Consumption NET Usage
Now 0.786 kW 0.255 kW -0.531 kW
Today 1.418 kWh (0.128 kW) 6.559 kWh (0.591 kW) 5.141 kWh (0.463 kW)
  - This Week 43.979 kWh (17.858 kWh/day) 78.705 kWh (31.959 kWh/day) 34.726 kWh (14.101 kWh/day)
  - This Month 43.979 kWh (17.858 kWh/day) 78.705 kWh (31.959 kWh/day) 34.726 kWh (14.101 kWh/day)
  - This Year 0.289 MWh (8.649 kWh/day) 0.662 MWh (19.780 kWh/day) 0.372 MWh (11.132 kWh/day)
Yesterday 20.377 kWh (0.849 kW) 15.260 kWh (0.636 kW) -5.117 kWh (-0.213 kW)
Last 7 Days 83.390 kWh (12.756 kWh/day) 140.327 kWh (21.465 kWh/day) 56.937 kWh (8.709 kWh/day)
Last 30 Days 259.466 kWh (8.784 kWh/day) 606.974 kWh (20.549 kWh/day) 347.508 kWh (11.765 kWh/day)
Last One Year 6.110 MWh (16.761 kWh/day) 7.548 MWh (20.705 kWh/day) 1.438 MWh (3.945 kWh/day)
Lifetime Since PTO 35.855 MWh (17.250 kW/day) 40.173 MWh (19.328 kW/day) 4.318 MWh (2.078 kW/day)
Lifetime Since Install 35.889 MWh 40.753 MWh 4.864 MWh
Voltage/Current 250.0 V / 3.1 A 249.9 V / 1.0 A 250.0 V / -2.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/10/2022 22:08 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.182 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.288 2.350 2.157 12.445 0.000 kW
2.230 kWh
0.000 kW
13.379 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.283 2.211 2.039 11.734
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 2.265 2.068 12.135
04 - 202232****** IQ7+ [5] VCOP 0.000 0.294 2.266 2.070 11.905
05 - 202244****** IQ7+M [5] VCOP 0.000 0.286 2.062 1.908 11.260
06 - 202245****** IQ7+M [5] VCOP 0.000 0.279 2.225 2.074 11.872
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.287 2.139 1.961 11.236 0.000 kW
2.112 kWh
0.000 kW
10.561 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.289 2.061 1.869 10.914
09 - 202217****** IQ7+ [5] VCOP 0.000 0.286 2.053 1.917 11.017
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 2.140 1.979 11.301
11 - 202224****** IQ7+M [5] VCOP 0.000 0.286 2.168 1.992 11.401
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.265 2.344 2.120 12.037 0.000 kW
2.311 kWh
0.000 kW
9.243 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.262 2.235 2.039 11.678
14 - 202216****** IQ7+ [5] VC-- 0.000 0.268 2.365 2.134 12.139
15 - 202245****** IQ7+M [5] VCOP 0.000 0.264 2.298 2.102 11.917
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -4.94 A (-0.263 kW)
Remain Capacity/Energy 495.0 Ah (25.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.5 % State Of Health 100.0 %
Run Time 4d 4h 12m to empty Report Date 2022-07-10 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.20 V Cell (MIN/MAX) 3.320 V / 3.330 V (0.010 V)
Current/Power -1.55 A (-82 W) Runtime 4d 10h 27m to empty
Remain Capacity/Energy 165.0 Ah (8.4 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 82.5 % State Of Health 100.0 %
Temperature 25.0 °C Cycle 69
MOSFET CFET = ON, DFET = ON Reported 2022-07-10 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.320 V 3.320 V 3.322 V 3.322 V 3.323 V 3.322 V 3.323 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.325 V 3.327 V 3.326 V 3.329 V 3.328 V 3.330 V 3.329 V
pack voltage and current cell voltages
pack temperature
Voltage 53.16 V Cell (MIN/MAX) 3.322 V / 3.322 V (0.000 V)
Current/Power -0.81 A (-43 W) Runtime 4d 19h 2m to empty
Remain Capacity/Energy 93.1 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.1 % State Of Health 100.0 %
Temperature 24.4 °C Cycle 20
MOSFET CFET = ON, DFET = ON Reported 2022-07-10 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.323 V / 3.325 V (0.002 V)
Current/Power -0.87 A (-46 W) Runtime 4d 10h 4m to empty
Remain Capacity/Energy 92.2 Ah (4.7 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 92.2 % State Of Health 100.0 %
Temperature 25.9 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-07-10 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.324 V 3.325 V 3.325 V 3.324 V 3.325 V 3.324 V 3.325 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.324 V 3.325 V 3.324 V 3.324 V 3.324 V 3.325 V 3.323 V
pack voltage and current cell voltages
pack temperature
Voltage 53.15 V Cell (MIN/MAX) 3.321 V / 3.322 V (0.001 V)
Current/Power -0.89 A (-47 W) Runtime 4d 8h 0m to empty
Remain Capacity/Energy 92.2 Ah (4.7 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 92.2 % State Of Health 100.0 %
Temperature 26.0 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-07-10 23:51
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.322 V 3.321 V 3.321 V 3.321 V 3.322 V 3.321 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.322 V 3.321 V 3.322 V 3.321 V 3.321 V 3.322 V
pack voltage and current cell voltages
pack temperature
Voltage 53.16 V Cell (MIN/MAX) 3.322 V / 3.323 V (0.001 V)
Current/Power -0.85 A (-45 W) Runtime 4d 12h 20m to empty
Remain Capacity/Energy 92.3 Ah (4.7 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 92.6 % State Of Health 99.7 %
Temperature 24.5 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-07-10 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.323 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
pack voltage and current cell voltages
pack temperature