Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.318 kW
03/14/2026 16:55 (2117 days) Production Consumption NET Usage
Now 2.650 kW 0.332 kW -2.318 kW
Today 29.763 kWh (1.758 kW) 10.065 kWh (0.594 kW) -19.698 kWh (-1.163 kW)
  - This Week 136.597 kWh (20.370 kWh/day) 92.673 kWh (13.820 kWh/day) -43.924 kWh (-6.550 kWh/day)
  - This Month 230.305 kWh (16.804 kWh/day) 198.972 kWh (14.518 kWh/day) -31.333 kWh (-2.286 kWh/day)
  - This Year 0.864 MWh (11.887 kWh/day) 1.299 MWh (17.864 kWh/day) 0.435 MWh (5.977 kWh/day)
Yesterday 20.551 kWh (0.855 kW) 13.313 kWh (0.554 kW) -7.238 kWh (-0.301 kW)
Last 7 Days 136.998 kWh (19.571 kWh/day) 98.584 kWh (14.083 kWh/day) -38.414 kWh (-5.488 kWh/day)
Last 30 Days (02/12/2026) 383.905 kWh (12.797 kWh/day) 490.757 kWh (16.359 kWh/day) 106.852 kWh (3.562 kWh/day)
Last One Year 6.019 MWh (16.491 kWh/day) 7.828 MWh (21.447 kWh/day) 1.809 MWh (4.956 kWh/day)
Lifetime Since PTO 36.430 MWh (17.203 kW/day) 40.810 MWh (19.271 kW/day) 4.380 MWh (2.068 kW/day)
Lifetime Since Install 36.464 MWh 41.390 MWh 4.926 MWh
Voltage/Current 251.9 V / 10.5 A 251.7 V / 1.3 A 251.8 V / -9.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/10/2022 21:45 (12.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.104 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.690 1.825 7.823 0.000 kW
1.646 kWh
0.000 kW
9.874 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.609 1.748 7.512
03 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.732 1.827 7.872
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.677 1.808 7.706
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.600 1.739 7.387
06 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.566 1.712 7.262
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.648 1.784 7.262 0.000 kW
1.715 kWh
0.000 kW
8.574 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.740 1.888 7.550
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.720 1.844 7.406
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.712 1.888 7.604
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.754 1.890 7.592
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.238 1.428 1.552 7.118 0.000 kW
1.414 kWh
0.000 kW
5.656 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.239 1.402 1.532 7.066
14 - 202216****** IQ7+ [5] VCOP 0.000 0.240 1.440 1.548 7.144
15 - 202245****** IQ7+M [5] VCOP 0.000 0.237 1.386 1.504 6.890
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.28 V Current/Power -1.41 A (-75 W)
Remain Capacity/Energy 439.2 Ah (22.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 73.2 % State Of Health 100.0 %
Run Time 12d 23h 29m to empty Report Date 2022-09-10 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.