Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.916 kW
04/29/2026 13:34 (2163 days) Production Consumption NET Usage
Now 4.321 kW 0.405 kW -3.916 kW
Today 11.977 kWh (0.882 kW) 3.825 kWh (0.282 kW) -8.152 kWh (-0.600 kW)
  - This Week 84.828 kWh (23.784 kWh/day) 33.278 kWh (9.330 kWh/day) -51.550 kWh (-14.453 kWh/day)
  - This Month 705.402 kWh (24.694 kWh/day) 479.708 kWh (16.793 kWh/day) -225.694 kWh (-7.901 kWh/day)
  - This Year 1.935 MWh (16.318 kWh/day) 2.045 MWh (17.248 kWh/day) 0.110 MWh (0.930 kWh/day)
Yesterday 16.536 kWh (0.689 kW) 7.784 kWh (0.324 kW) -8.752 kWh (-0.365 kW)
Last 7 Days 151.025 kWh (21.575 kWh/day) 60.026 kWh (8.575 kWh/day) -90.999 kWh (-13.000 kWh/day)
Last 30 Days (03/30/2026) 735.911 kWh (24.530 kWh/day) 497.870 kWh (16.596 kWh/day) -238.041 kWh (-7.935 kWh/day)
Last One Year 6.271 MWh (17.182 kWh/day) 7.825 MWh (21.437 kWh/day) 1.553 MWh (4.256 kWh/day)
Lifetime Since PTO 37.501 MWh (17.333 kW/day) 41.556 MWh (19.207 kW/day) 4.055 MWh (1.874 kW/day)
Lifetime Since Install 37.534 MWh 42.136 MWh 4.601 MWh
Voltage/Current 254.1 V / 17.0 A 254.1 V / 1.6 A 254.1 V / -15.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/18/2022 22:50 (9.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.368 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.275 1.064 1.043 4.939 0.000 kW
1.039 kWh
0.000 kW
6.233 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.268 1.015 1.014 4.723
03 - 202224****** IQ7+M [5] VCOP 0.000 0.274 1.061 1.032 4.930
04 - 202232****** IQ7+ [5] VCOP 0.000 0.273 1.028 1.039 4.860
05 - 202244****** IQ7+M [5] VCOP 0.000 0.272 1.051 1.021 4.837
06 - 202245****** IQ7+M [5] VCOP 0.000 0.267 1.015 1.002 4.731
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.027 1.129 5.129 0.000 kW
1.181 kWh
0.000 kW
5.907 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.188 1.209 5.486
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.266 1.273 5.781
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.250 1.274 5.720
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.176 1.243 5.546
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.142 0.527 0.488 2.849 0.000 kW
0.557 kWh
0.000 kW
2.227 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.154 0.565 0.548 3.053
14 - 202216****** IQ7+ [5] VCOP 0.000 0.156 0.573 0.540 3.068
15 - 202245****** IQ7+M [5] VCOP 0.000 0.153 0.561 0.534 2.986
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.32 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 392.4 Ah (20.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 65.4 % State Of Health 100.0 %
Run Time 10d 21h 36m to empty Report Date 2022-11-18 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.35 V Cell (MIN/MAX) 3.328 V / 3.338 V (0.010 V)
Current/Power -0.51 A (-26 W) Runtime 10d 19h 0m to empty
Remain Capacity/Energy 130.8 Ah (6.7 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 65.4 % State Of Health 100.0 %
Temperature 20.0 °C Cycle 84
MOSFET CFET = ON, DFET = ON Reported 2022-11-18 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.328 V 3.330 V 3.330 V 3.331 V 3.331 V 3.332 V 3.333 V 3.333 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.334 V 3.335 V 3.335 V 3.336 V 3.337 V 3.337 V 3.338 V 3.337 V
pack voltage and current cell voltages
pack temperature
Voltage 53.30 V Cell (MIN/MAX) 3.331 V / 3.332 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 21.2 °C Cycle 33
MOSFET CFET = ON, DFET = ON Reported 2022-11-18 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.331 V 3.332 V 3.332 V 3.331 V 3.331 V 3.332 V 3.331 V 3.332 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.331 V 3.331 V 3.331 V 3.331 V 3.331 V 3.331 V 3.331 V 3.331 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_2.png". Check that the process running PHP has enough permission.