Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.498 kW
12/21/2025 18:34 (2034 days) Production Consumption NET Usage
Now 0.000 kW 0.498 kW 0.498 kW
Today 9.597 kWh (0.516 kW) 12.366 kWh (0.665 kW) 2.769 kWh (0.149 kW)
  - This Week 9.597 kWh (12.395 kWh/day) 12.366 kWh (15.972 kWh/day) 2.769 kWh (3.576 kWh/day)
  - This Month 184.503 kWh (8.881 kWh/day) 435.647 kWh (20.970 kWh/day) 251.144 kWh (12.089 kWh/day)
  - This Year 6.053 MWh (17.063 kWh/day) 7.352 MWh (20.723 kWh/day) 1.298 MWh (3.660 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.504 MWh (17.448 kW/day) 39.305 MWh (19.316 kW/day) 3.800 MWh (1.868 kW/day)
Lifetime Since Install 35.538 MWh 39.885 MWh 4.346 MWh
Voltage/Current 248.9 V / 0.0 A 248.8 V / 2.0 A 248.9 V / 2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/16/2022 21:56 (14.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.905 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.280 1.114 1.684 14.343 0.000 kW
1.075 kWh
0.000 kW
6.451 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.265 1.036 1.628 13.556
03 - 202224****** IQ7+M [0] ---- 0.000 0.278 1.110 1.648 13.865
04 - 202232****** IQ7+ [0] ---- 0.000 0.283 1.091 1.643 13.802
05 - 202244****** IQ7+M [0] ---- 0.000 0.276 1.031 1.489 12.676
06 - 202245****** IQ7+M [0] ---- 0.000 0.274 1.070 1.638 13.674
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.251 0.979 1.537 13.066 0.000 kW
0.981 kWh
0.000 kW
4.904 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.240 0.966 1.483 12.599
09 - 202217****** IQ7+ [0] ---- 0.000 0.251 0.992 1.488 12.706
10 - 202244****** IQ7+M [0] ---- 0.000 0.253 0.975 1.531 13.128
11 - 202224****** IQ7+M [0] ---- 0.000 0.254 0.991 1.550 13.229
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.269 1.128 1.678 14.233 0.000 kW
1.137 kWh
0.000 kW
4.550 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.267 1.127 1.644 13.711
14 - 202216****** IQ7+ [0] ---- 0.000 0.274 1.153 1.691 14.316
15 - 202245****** IQ7+M [0] ---- 0.000 0.273 1.142 1.641 14.015
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.35 A (-71 W)
Remain Capacity/Energy 517.8 Ah (26.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.3 % State Of Health 100.0 %
Run Time 15d 23h 33m to empty Report Date 2022-07-16 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.