Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.591 kW
01/28/2026 09:16 (2072 days) Production Consumption NET Usage
Now 0.027 kW 4.618 kW 4.591 kW
Today 0.010 kWh (0.001 kW) 3.031 kWh (0.326 kW) 3.021 kWh (0.325 kW)
  - This Week 0.368 kWh (0.109 kWh/day) 48.180 kWh (14.225 kWh/day) 47.812 kWh (14.116 kWh/day)
  - This Month 206.266 kWh (7.532 kWh/day) 532.410 kWh (19.440 kWh/day) 326.144 kWh (11.909 kWh/day)
  - This Year 0.206 MWh (7.532 kWh/day) 0.532 MWh (19.440 kWh/day) 0.326 MWh (11.909 kWh/day)
Yesterday 0.329 kWh (0.014 kW) 12.679 kWh (0.528 kW) 12.350 kWh (0.515 kW)
Last 7 Days 47.833 kWh (6.833 kWh/day) 138.582 kWh (19.796 kWh/day) 90.749 kWh (12.963 kWh/day)
Last 30 Days 225.610 kWh (7.520 kWh/day) 578.011 kWh (19.267 kWh/day) 352.401 kWh (11.747 kWh/day)
Last One Year 6.105 MWh (16.725 kWh/day) 7.491 MWh (20.523 kWh/day) 1.386 MWh (3.798 kWh/day)
Lifetime Since PTO 35.772 MWh (17.261 kW/day) 40.044 MWh (19.322 kW/day) 4.272 MWh (2.061 kW/day)
Lifetime Since Install 35.806 MWh 40.624 MWh 4.818 MWh
Voltage/Current 248.1 V / 0.1 A 248.0 V / 18.6 A 248.0 V / 18.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/07/2022 23:04 (11.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.857 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.113 0.478 0.238 9.845 0.000 kW
0.468 kWh
0.000 kW
2.809 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.110 0.459 0.218 9.426
03 - 202224****** IQ7+M [5] VCOP 0.000 0.113 0.485 0.238 9.850
04 - 202232****** IQ7+ [5] VCOP 0.000 0.112 0.467 0.229 9.709
05 - 202244****** IQ7+M [5] VC-- 0.000 0.108 0.461 0.224 9.241
06 - 202245****** IQ7+M [5] VCOP 0.000 0.110 0.459 0.228 9.110
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.102 0.430 0.209 9.394 0.000 kW
0.432 kWh
0.000 kW
2.160 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.102 0.433 0.211 9.533
09 - 202217****** IQ7+ [5] VC-- 0.000 0.102 0.431 0.213 9.325
10 - 202244****** IQ7+M [0] ---- 0.000 0.103 0.432 0.211 9.707
11 - 202224****** IQ7+M [0] -C-- 0.000 0.102 0.434 0.211 9.713
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.107 0.467 0.229 8.639 0.000 kW
0.472 kWh
0.000 kW
1.888 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.110 0.475 0.234 8.408
14 - 202216****** IQ7+ [0] ---- 0.000 0.110 0.480 0.236 8.687
15 - 202245****** IQ7+M [5] VC-- 0.000 0.109 0.465 0.228 8.416
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.