Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.238 kW
02/07/2026 17:13 (2082 days) Production Consumption NET Usage
Now 0.344 kW 0.582 kW 0.238 kW
Today 15.705 kWh (0.911 kW) 6.566 kWh (0.381 kW) -9.139 kWh (-0.530 kW)
  - This Week 109.686 kWh (16.325 kWh/day) 136.797 kWh (20.360 kWh/day) 27.111 kWh (4.035 kWh/day)
  - This Month 109.686 kWh (16.325 kWh/day) 136.797 kWh (20.360 kWh/day) 27.111 kWh (4.035 kWh/day)
  - This Year 0.355 MWh (9.415 kWh/day) 0.720 MWh (19.088 kWh/day) 0.365 MWh (9.674 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 111.827 kWh (17.800 kWh/day) 144.342 kWh (22.976 kWh/day) 32.515 kWh (5.176 kWh/day)
Last 30 Days 273.253 kWh (9.332 kWh/day) 597.855 kWh (20.417 kWh/day) 324.602 kWh (11.086 kWh/day)
Last One Year 6.099 MWh (16.742 kWh/day) 7.568 MWh (20.775 kWh/day) 1.469 MWh (4.033 kWh/day)
Lifetime Since PTO 35.921 MWh (17.247 kW/day) 40.231 MWh (19.316 kW/day) 4.311 MWh (2.070 kW/day)
Lifetime Since Install 35.955 MWh 40.811 MWh 4.857 MWh
Voltage/Current 250.1 V / 1.4 A 250.2 V / 2.3 A 250.1 V / 1.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/12/2022 22:22 (10.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.026 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.246 1.443 1.583 9.975 0.000 kW
1.406 kWh
0.000 kW
8.439 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.243 1.385 1.501 9.485
03 - 202224****** IQ7+M [5] VCOP 0.000 0.248 1.444 1.555 9.867
04 - 202232****** IQ7+ [5] VCOP 0.000 0.247 1.397 1.507 9.606
05 - 202244****** IQ7+M [5] VCOP 0.000 0.246 1.409 1.516 9.620
06 - 202245****** IQ7+M [5] VCOP 0.000 0.239 1.361 1.485 9.359
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.283 1.388 1.577 9.861 0.000 kW
1.513 kWh
0.000 kW
7.567 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.284 1.523 1.720 10.569
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.567 1.744 10.718
10 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.556 1.741 10.726
11 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.533 1.742 10.807
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.165 0.985 0.990 6.527 0.000 kW
1.005 kWh
0.000 kW
4.020 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.164 1.007 1.012 6.713
14 - 202216****** IQ7+ [0] ---- 0.000 0.165 1.029 1.025 6.806
15 - 202245****** IQ7+M [0] ---- 0.000 0.164 1.000 0.996 6.590
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.29 A (-68 W)
Remain Capacity/Energy 522.6 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.1 % State Of Health 100.0 %
Run Time 16d 21h 6m to empty Report Date 2022-10-12 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.