Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.795 kW
07/05/2025 14:18 (1865 days) Production Consumption NET Usage
Now 2.876 kW 2.081 kW -0.795 kW
Today 17.800 kWh (1.242 kW) 7.913 kWh (0.552 kW) -9.887 kWh (-0.690 kW)
  - This Week 174.069 kWh (26.388 kWh/day) 217.759 kWh (33.011 kWh/day) 43.690 kWh (6.623 kWh/day)
  - This Month 116.783 kWh (25.402 kWh/day) 150.077 kWh (32.644 kWh/day) 33.294 kWh (7.242 kWh/day)
  - This Year 3.146 MWh (16.953 kWh/day) 3.277 MWh (17.658 kWh/day) 0.131 MWh (0.705 kWh/day)
Yesterday 33.170 kWh (1.383 kW) 53.473 kWh (2.229 kW) 20.303 kWh (0.846 kW)
Last 7 Days 177.451 kWh (25.352 kWh/day) 233.676 kWh (33.385 kWh/day) 56.225 kWh (8.033 kWh/day)
Last 30 Days 615.341 kWh (20.511 kWh/day) 853.443 kWh (28.448 kWh/day) 238.102 kWh (7.937 kWh/day)
Last One Year 6.315 MWh (17.302 kWh/day) 6.414 MWh (17.572 kWh/day) 0.098 MWh (0.270 kWh/day)
Lifetime Since PTO 32.597 MWh (17.473 kW/day) 35.229 MWh (18.884 kW/day) 2.632 MWh (1.411 kW/day)
Lifetime Since Install 32.631 MWh 35.809 MWh 3.178 MWh
Voltage/Current 248.2 V / 11.6 A 248.1 V / 8.4 A 248.1 V / -3.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/03/2022 22:00 (12.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.420 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.070 0.381 2.204 9.131 0.000 kW
0.368 kWh
0.000 kW
2.210 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.067 0.353 2.093 8.670
03 - 202224****** IQ7+M [5] VCOP 0.000 0.070 0.381 2.203 9.206
04 - 202232****** IQ7+ [5] VCOP 0.000 0.069 0.372 2.140 8.912
05 - 202244****** IQ7+M [5] VCOP 0.000 0.068 0.358 2.104 8.650
06 - 202245****** IQ7+M [5] VCOP 0.000 0.068 0.365 2.017 8.437
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.084 0.351 2.118 8.443 0.000 kW
0.349 kWh
0.000 kW
1.747 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.082 0.346 2.212 8.777
09 - 202217****** IQ7+ [5] VCOP 0.000 0.068 0.344 2.118 8.591
10 - 202244****** IQ7+M [5] VCOP 0.000 0.084 0.352 2.211 8.879
11 - 202224****** IQ7+M [5] VCOP 0.000 0.084 0.355 2.245 9.005
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.070 0.362 1.697 8.369 0.000 kW
0.366 kWh
0.000 kW
1.462 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.070 0.363 1.633 8.220
14 - 202216****** IQ7+ [5] VCOP 0.000 0.071 0.372 1.706 8.453
15 - 202245****** IQ7+M [5] VCOP 0.000 0.071 0.366 1.673 8.319
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.85 V Current/Power -2.19 A (-0.116 kW)
Remain Capacity/Energy 331.8 Ah (17.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 55.3 % State Of Health 100.0 %
Run Time 6d 7h 30m to empty Report Date 2022-04-03 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.