Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.629 kW
06/30/2025 17:09 (1860 days) Production Consumption NET Usage
Now 1.760 kW 2.389 kW 0.629 kW
Today 25.377 kWh (1.477 kW) 18.219 kWh (1.060 kW) -7.158 kWh (-0.417 kW)
  - This Week 55.335 kWh (32.257 kWh/day) 55.238 kWh (32.200 kWh/day) -0.097 kWh (-0.057 kWh/day)
  - This Month 626.624 kWh (21.087 kWh/day) 760.872 kWh (25.605 kWh/day) 134.248 kWh (4.518 kWh/day)
  - This Year 3.028 MWh (16.754 kWh/day) 3.115 MWh (17.236 kWh/day) 0.087 MWh (0.482 kWh/day)
Yesterday 29.958 kWh (1.249 kW) 37.019 kWh (1.543 kW) 7.061 kWh (0.294 kW)
Last 7 Days 164.939 kWh (23.565 kWh/day) 274.127 kWh (39.165 kWh/day) 109.188 kWh (15.600 kWh/day)
Last 30 Days 617.926 kWh (20.598 kWh/day) 775.650 kWh (25.855 kWh/day) 157.724 kWh (5.257 kWh/day)
Last One Year 6.346 MWh (17.387 kWh/day) 6.392 MWh (17.513 kWh/day) 0.046 MWh (0.126 kWh/day)
Lifetime Since PTO 32.479 MWh (17.455 kW/day) 35.067 MWh (18.846 kW/day) 2.588 MWh (1.391 kW/day)
Lifetime Since Install 32.513 MWh 35.647 MWh 3.134 MWh
Voltage/Current 247.4 V / 7.1 A 247.4 V / 9.7 A 247.4 V / 2.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/05/2022 21:46 (12.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.457 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.270 1.010 1.640 8.650 0.000 kW
0.980 kWh
0.000 kW
5.882 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.269 0.958 1.563 8.203
03 - 202224****** IQ7+M [5] VCOP 0.000 0.272 1.017 1.650 8.706
04 - 202232****** IQ7+ [5] VCOP 0.000 0.272 0.980 1.606 8.454
05 - 202244****** IQ7+M [5] VCOP 0.000 0.269 0.974 1.519 8.187
06 - 202245****** IQ7+M [5] VCOP 0.000 0.266 0.942 1.499 7.978
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.268 0.936 1.491 8.029 0.000 kW
0.946 kWh
0.000 kW
4.730 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.271 0.949 1.586 8.340
09 - 202217****** IQ7+ [5] VCOP 0.000 0.268 0.953 1.559 8.155
10 - 202244****** IQ7+M [5] VCOP 0.000 0.272 0.941 1.583 8.414
11 - 202224****** IQ7+M [5] VCOP 0.000 0.270 0.951 1.601 8.529
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.242 0.954 1.570 7.865 0.000 kW
0.961 kWh
0.000 kW
3.844 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.241 0.955 1.552 7.728
14 - 202216****** IQ7+ [5] VCOP 0.000 0.245 0.972 1.577 7.940
15 - 202245****** IQ7+M [5] VCOP 0.000 0.242 0.963 1.554 7.813
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.