Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.766 kW
10/29/2025 14:07 (1981 days) Production Consumption NET Usage
Now 1.044 kW 0.278 kW -0.766 kW
Today 7.914 kWh (0.560 kW) 4.548 kWh (0.322 kW) -3.366 kWh (-0.238 kW)
  - This Week 51.506 kWh (14.351 kWh/day) 16.998 kWh (4.736 kWh/day) -34.508 kWh (-9.615 kWh/day)
  - This Month 462.592 kWh (16.181 kWh/day) 441.938 kWh (15.458 kWh/day) -20.654 kWh (-0.722 kWh/day)
  - This Year 5.562 MWh (18.442 kWh/day) 6.297 MWh (20.879 kWh/day) 0.735 MWh (2.437 kWh/day)
Yesterday 9.301 kWh (0.388 kW) 13.812 kWh (0.575 kW) 4.511 kWh (0.188 kW)
Last 7 Days 95.910 kWh (13.701 kWh/day) 35.599 kWh (5.086 kWh/day) -60.311 kWh (-8.616 kWh/day)
Last 30 Days 486.248 kWh (16.208 kWh/day) 466.769 kWh (15.559 kWh/day) -19.479 kWh (-0.649 kWh/day)
Last One Year 6.227 MWh (17.061 kWh/day) 7.399 MWh (20.271 kWh/day) 1.172 MWh (3.210 kWh/day)
Lifetime Since PTO 35.013 MWh (17.669 kW/day) 38.249 MWh (19.302 kW/day) 3.236 MWh (1.633 kW/day)
Lifetime Since Install 35.047 MWh 38.829 MWh 3.782 MWh
Voltage/Current 253.4 V / 4.1 A 253.4 V / 1.1 A 253.4 V / -3.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/05/2022 21:50 (12.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.836 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.251 1.050 1.151 11.890 0.000 kW
1.015 kWh
0.000 kW
6.089 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.246 1.004 1.092 11.417
03 - 202224****** IQ7+M [5] VCOP 0.000 0.253 1.031 1.149 11.946
04 - 202232****** IQ7+ [5] VCOP 0.000 0.256 1.025 1.105 11.774
05 - 202244****** IQ7+M [5] VCOP 0.000 0.248 0.997 1.072 11.228
06 - 202245****** IQ7+M [5] VCOP 0.000 0.243 0.981 1.068 11.091
front 07 - 202206****** IQ7+ [5] VC-- 0.000 0.250 0.924 0.995 11.650 0.000 kW
0.956 kWh
0.000 kW
4.778 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.253 0.964 1.009 11.775
09 - 202217****** IQ7+ [5] VCOP 0.000 0.250 0.955 1.002 11.511
10 - 202244****** IQ7+M [5] VCOP 0.000 0.253 0.967 1.046 11.966
11 - 202224****** IQ7+M [5] VCOP 0.000 0.250 0.967 1.004 11.985
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.225 0.980 1.038 10.128 0.000 kW
0.992 kWh
0.000 kW
3.969 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.228 1.009 1.018 9.723
14 - 202216****** IQ7+ [5] VCOP 0.000 0.228 0.995 1.021 10.174
15 - 202245****** IQ7+M [5] VCOP 0.000 0.221 0.985 0.931 9.862
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.